Setting the Cup Stand Overflow Detection

By default, the overflow detection for the cup stand is set at approximately 8-oz. This means
that when 8-oz of liquid have accumulated in the cup stand, the "Empty Cup Stand" message
appears on the screen. By adjusting the position of one of the cup stand overflow sensors, you
can increase the amount of liquid in the cup stand to 24-oz before the "Empty Cup Stand"
message appears.

Installing a Cup Stand Drain

Alternatively, you can drill open the drain fitting at the rear of the cup stand to install a drain
hose that can be routed either into a large waste bin under the cabinet (easily done if a waste
chute system is used) or into an actual drain.
20