System Status Screen

Code Message Displayed
Electronic Board Communication Lost
--
Please Call for Service or Press
Acknowledge to Retry
Blower & Fan current is over safety
level
B1
Blower & Fan current is under
minimum operation level
D2
LED in Waste Bin detector has a fault
D3
Machine's door is open.
D6
Cup is present in dispensing area.
Coffee Grinder Over Current Standby
Grinder Fuse Fault
Grinder Sensor Error
Grinder's current is close to critical
level
G1
Grinder's current is close to minimum
operation level
Grinder's current is over safety level
Grinder's current is under minimum
operation level
104
Condition
Communication between the
control board and HMI is lost.
Blower & Fan current is above the
recommended safety level. Fan may
be drawing too much power.
Blower & Fan current is below the
minimum operating level. Fan may
not be drawing enough power.
The IR LED of the waste bin sensor
voltage is over the configured
maximum operation level.
The front door of the machine is
open.
A cup has been detected in the
dispensing area.
The grinder current was over the
stand by operation level.
Grinder fuse has triggered a fault.
Grinder Current Sensor is out of range.
Grinder current is close to maximum
operating level. Grinder may be
drawing too much power.
Grinder current is close to minimum
operating level. Grinder may not be
drawing enough power.
Grinder current has exceeded the
maximum operating level.
Grinder current is below the
minimum operating level.
Action(s) Required
1 - Press "Acknowledge" to reset
2 - Reboot the machine.
3 - If message persists, check the
HMI, Control Board and wiring.
1 - Check the wiring and
connections for the powder system
blower.
2 - Clean any accumulation from the
blower.
3 - If message persists, replace the
powder system blower.
1 - Check wiring and connections for
the powder system blower.
2 - If message persists, replace the
powder system blower.
1 - Clear the message.
2 - Reboot the machine.
3 - If message persists, replace the
waste bin presence sensor.
1 - Close the front door.
2 - If message persists, check or
replace the front door sensor.
If no cup is present, clean the cup
detection LEDs.
1 - Clear the message.
2 - Reboot the machine.
1 - Grinder may be jammed – clear
grinder jam.
2 - Check the fuse on the control
board.
1 - Clear the message.
2 - Reboot the machine.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
1 - Reboot the machine.
2 - If message persists, replace the
grinder.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
1 - Check the condition of the
grinder belt.
2 - Check the wiring and
connections to the grinder.
3 - The grinder may need to be
replaced.