Section 4 - Care And Maintenance; Daily Care; Every 1-2 Weeks; Every 15,000 Cycles Or 12 Months - VKI Technologies Eccellenza momentum Operation Manual

Hide thumbs Also See for Eccellenza momentum:
Table of Contents

Advertisement

Care and Maintenance
To keep the Eccellenza Momentum running efficiently and at peak performance, the following
maintenance procedures must be performed at their specified intervals. It is recommended that
equipment maintenance be scheduled at a time that would be the least disruptive to your
customers. Whenever possible, replace the components requiring maintenance with new or
refurbished ones, and then refurbish the older components at your shop.
Failure to perform the required care and maintenance will result in poor
beverage quality and will lead to equipment malfunctions. It may also void
any remaining warranty on the equipment and its components.

Daily Care

► Empty the Cup Stand – empty the contents of the cup stand and rinse the stand
and grill under clean running water.
► Empty the Waste Bin – empty the contents of the waste bin.
► Refill the Coffee Dispensers and Powder Dispensers – top off the coffee and
powder dispensers.
► Wipe Exterior and Countertop – using a clean towel, wipe any coffee grounds and
spills from the exterior of the machine, and from the countertop on which it sits.

Every 1-2 Weeks

► Clean the whipper components - for detailed information about disassembling and
cleaning the whipper components, consult the Momentum Service Manual (VKI
Publication #202378-001).
► Inspect Water Hoses and Tubing - inspect all plumbing connections, water hoses,
tubing, clamps, fittings and water related components (valves, water tank, etc.) for
signs of wear or damage. Replace them, if required.

Every 15,000 Cycles or 12 Months

► Inspect Electrical Wiring and Components - inspect all of the equipment wiring,
terminals, connectors and electrical components (valves, motors, relays, element, etc.) for
signs of wear, damage or overheating at connection points. Replace them, if required.
► Clean the whipper hoses - remove all three whipper outlet hoses and thoroughly
clean the exterior and the interior of each of the hoses. A plastic bristled brush (VKI
P/N - 202477-001) must be used to clean the interior of the hoses.
VKI Publication #202377-001