Pilz PMI v507 Operating Manual

Operator terminals

Advertisement

Quick Links

PMI v507, PMI v512
}
Operator terminals
Operating Manual 1003981-EN-01

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PMI v507

  • Page 1 PMI v507, PMI v512 Operator terminals Operating Manual 1003981-EN-01...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    General wiring guidelines 6.1.1 Shielding 6.1.2 Measures to protect against interference voltages Connecting the Unit 6.2.1 Supply voltage 6.2.2 Connection example 6.2.3 Interfaces Section 7 Putting into Service Activating the setup Control Panel Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 4 7.2.4 Network and dial-up 7.2.5 Regional settings 7.2.6 Storage Manager 7.2.7 System 7.2.8 Network servers Section 8 Care and Maintenance Cleaning the touchscreen Section 9 Technical details Section 10 Order reference 10.1 Product Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 5: Operating Manual Pmi V507, Pmi V512

    This describes a situation in which the product or devices could be dam- aged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import- ance. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 6 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 7: Overview

    512 MB Flash 1 serial interface 1 Ethernet interface 1 USB slave interface 2 USB host interfaces Battery-buffered real-time clock Pre-installed software: – PASvisu Server – PASvisu Viewer PMI – PSS 4000 Firmware (OPC Server) Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 8: Front View

    Operator terminal 6 retaining clamps Connector plug for power supply Projection stand PMI v512 Operator terminal 8 retaining clamps Mounting frame for achieving protection class IP66 Connector plug for power supply Projection stand Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 9: Safety

    If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 10: Safety Regulations

    When installing the unit within a control cabinet, you must ensure the ventilation slots are not obstructed, otherwise the unit could be damaged through overheating. Protect the unit from direct sunlight and dust. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 11: Measures To Protect Against Interference

    Do not pour liquids over the unit or insert any objects into the unit. When in storage and during operation, protect the unit from vibration and shock. Avoid using chemicals close to the system. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 12: Maintenance

    Maintenance Do not use thinners or organic solvents to clean the unit and touchscreen surface. Further information on care and maintenance of the touchscreen can be found in the chapter "Care and Maintenance". Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 13: Function Description

    Side view [8] [9] Legend [1] Audio interface LINE OUT [2] SD/SDHC card [3] Ethernet interface (100 BaseTX) [4] Supply voltage [5] Serial interface COM1 (RS232) [6] USB Slave [7] USB Host 1 Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 14 Function description [8] USB Host 2 [9] Functional earth Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 15: Installation

    Do not use chemicals close to the system. Ensure the maximum ambient and operating temperatures are not exceeded. Ensure that neither liquids nor objects can enter the unit at any time. Do not position the system close to flammable materials. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 16: Dimensions

    200 + 1 (7.874" + 0.039") 316 + 1 (12.441" + 0.039") h4/mm 137 + 1 (5.394" + 0.039") 206 + 1 (8.11" + 0.039") h*/t* = Dimensions without connections Allow extra for hardware connections! Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 17: Installing The Unit

    Ensure the information given for the ambient and operating temperatures in the tech- nical details is observed. Protection type IP65 (PMI v507)/IP66 (PMI v512) is only guaranteed when – the fixing screws are tightened as follows: min. 0.3 Nm, max. 0.5 Nm.
  • Page 18 Installation Fig.: Installing the PMI v512 Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 19: Wiring

    If strong magnetic fields are present, we recommend you use a bulkhead separator, i.e. metal sheet (MU-metal). Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 20: Connecting The Unit

    Fig.: Layout of supply voltage connector 1: Functional earth 2: 0 V 3: + 24 V DC UL requirement: Use a 24 VDC power supply (isolating source). Connect a max. 5 A fuse between the power supply and PMI. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 21: Connection Example

    INFORMATION To reduce interference, position a split ferrite on the 24 V and GND line, at a distance of approx. 100 mm from the PMI. Loop the cable once around the ferrite core. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 22: Interfaces

    Wiring 6.2.3 Interfaces Pin assignment of RS232 interface (COM1) n.c. n.c. n.c. n.c. n.c. = Not connected Fig.: Pin assignment of RS232 interface, Sub-D connector, 9-pin Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 23: Putting Into Service

    All system settings can be made from the Control Panel of Windows Embedded Compact Special features and device-specific settings are described in the following! 7.2.1 Date/time Setting the date, time, time zone and winter/summer time Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 24: Display

    Setting the keyboard layout (German or English) and setting the soft keyboard (small, large or no keyboard) 7.2.4 Network and dial-up Modify existing connections (e.g. IP address) or set new connections (PPP over Ethernet) 7.2.5 Regional settings Regional settings (number format, currency, time, date) Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 25: Storage Manager

    Putting into Service 7.2.6 Storage Manager Format/partition memory 7.2.7 System Display/modify system properties (relationship between program memory/file management) 7.2.8 Network servers Start and stop various services (Telnet, SMB, FTP, SNTP, Web Server) Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 26: Care And Maintenance

    Make sure the unit is switched off before cleaning it. This prevents you from accidentally triggering functions when you touch the touchscreen. Cleaning agents Only use water and washing-up liquid or window cleaner to dampen the cloth. Never use aggressive solvents or abrasive cleaning agents. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 27: Technical Details

    In accordance with the standard EN 60068-2-78 EN 60068-2-78 Humidity 90 % r. h. at 40 °C 90 % r. h. at 40 °C Condensation during operation Not permitted Not permitted EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 28 265507 265512 Dimensions Height 153 mm 222 mm Width 216 mm 332 mm Depth 65,4 mm 63,4 mm Weight 1.390 g 2.450 g Where standards are undated, the 2010-12 latest editions shall apply. Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 29: Order Reference

    Product Product type Features Order No. PMI v507 Operator terminal, 800 x 480 pixel resolution, ca- 265 507 pacitive touchscreen PMI v512 Operator terminal, 1280 x 800 pixel resolution, 265 512 capacitive touchscreen Operating Manual PMI v507, PMI v512 1003981-EN-01...
  • Page 30 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...

This manual is also suitable for:

Pmi v512265507265512

Table of Contents