  • Page 1 PMI 6 Operator terminals Operating Manual 1003280-EN-01...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Installation site and unit surroundings Dimensions Installing the unit Installation Section 6 Wiring General wiring guidelines 6.1.1 Shielding 6.1.2 Measures to protect against interference voltages Supply voltage Connection example Interfaces 6.4.1 RS232 interface (COM1) 6.4.2 CANopen interface Operating Manual PMI 6 1003280-EN-01...
  • Page 4 Various basic settings Section 8 Care and Maintenance Cleaning the touchscreen Section 9 Attachment Supported Windows components Windows CE Shell commands Windows CE Shell commands - Pilz expansions Section 10 Technical details Section 11 Order reference 11.1 Product Operating Manual PMI 6...
  • Page 5: Introduction

    CAUTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. Operating Manual PMI 6 1003280-EN-01...
  • Page 6 It also highlights areas within the text that are of particular import- ance. INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PMI 6 1003280-EN-01...
  • Page 7: Overview

    Character set: Unicode 1 SD card slot Memory: 512 MB DDR SDRAM 1 serial interface 1 Ethernet interface 1 CANopen interface 2 USB host interfaces Real-time clock User-specific applications and various visualisation software packages can be installed Operating Manual PMI 6 1003280-EN-01...
  • Page 8: Front View

    Front view Legend [1] Touchscreen (see Technical details [ 40]) Scope of supply Operator terminal Retaining clamps Connector plug for power supply Projection stand RJ45 cable for fieldbus junction box SD card as application memory Operating Manual PMI 6 1003280-EN-01...
  • Page 9: Safety

    This device is used to operate and monitor technical processes. The PMI offers the possibility of installing software from third-party suppliers. Pilz GmbH & Co. KG accepts no liability for any damages, nor does it provide support or any guarantee for the functional efficiency of the installed software.
  • Page 10: Safety Regulations

    When installing the device within a control cabinet, you must ensure the ventilation slots are not obstructed, otherwise the device could be damaged through overheating. Protect the device from direct sunlight and dust. Please note the guidelines given under “Installation”. Operating Manual PMI 6 1003280-EN-01...
  • Page 11: Measures To Protect Against Interference

    The maximum ambient temperature must not be exceeded when using the unit. Do not pour liquids over the unit or insert any objects into the unit. When in storage and during operation, protect the unit from vibration and shock. Avoid using chemicals close to the system. Operating Manual PMI 6 1003280-EN-01...
  • Page 12: Maintenance

    Safety 3.3.5 Maintenance Do not use thinners or organic solvents to clean the unit and touchscreen surface. Further information on care and maintenance of the touchscreen can be found in the chapter "Care and Maintenance". Operating Manual PMI 6 1003280-EN-01...
  • Page 13: Function Description

    The device is equipped with a real-time clock. Side view [1] [2] [3] [4] [10] [11] [12] [13] Legend [1] SD/SDHC card slot [2] Reset button [3] Status LED [4] Reserved [5] Reserved [6] Ethernet interface Operating Manual PMI 6 1003280-EN-01...
  • Page 14 Function description [7] Fieldbus junction box [8] Supply voltage +24 VDC [9] Serial interface COM1 (RS232) [10] USB Slave [11] USB Host 1 [12] USB Host 2 [13] Functional earth Operating Manual PMI 6 1003280-EN-01...
  • Page 15: Installation Safety

    Do not use chemicals close to the system. Ensure the maximum ambient and operating temperatures are not exceeded. Ensure that neither liquids nor objects can enter the device at any time. Do not position the system close to flammable materials. Operating Manual PMI 6 1003280-EN-01...
  • Page 16: Dimensions

    200 + 1 (7.874" + 0.039") 316 + 1 (12.441" + 0.039") h4/mm 137 + 1 (5.394" + 0.039") 206 + 1 (8.11" + 0.039") h*/t* = Dimensions without connections Allow extra for hardware connections! Operating Manual PMI 6 1003280-EN-01...
  • Page 17: Installing The Unit

    0.2 Nm, max. 0.4 Nm. – the gasket is not damaged. – the wall thickness is at least 2.5 mm. Installation Fig.: Installing the PMI 607 Control Fig.: Installing the PMI 612 Control Operating Manual PMI 6 1003280-EN-01...
  • Page 18: Wiring

    (e.g. RC networks). This is particularly important if these induct- ive loads are very close to the power supply or are fed from the same supply. If strong magnetic fields are present, we recommend you use a bulkhead separator, i.e. metal sheet (MU-metal). Operating Manual PMI 6 1003280-EN-01...
  • Page 19: Supply Voltage

    1: Functional earth 2: 0 V 3: + 24 V DC Connection example [4] [5] [4] [5] Fig.: Connection example Legende [1] Earth star point of the unit or control cabinet [2] Earth bus bar [3] Supply voltage Operating Manual PMI 6 1003280-EN-01...
  • Page 20: Interfaces

    0 V and are connected internally. Interfaces Connect X7 and X7 fieldbus to the fieldbus junction cable. 6.4.1 RS232 interface (COM1) 6.4.2 CANopen interface CAN_SHLD n.c. n.c. n.c. CAN_GND CAN_H CAN_L n.c. n.c. n.c. = not connected Operating Manual PMI 6 1003280-EN-01...
  • Page 21: Putting Into Service

    All system settings can be made from the Control Panel of Windows Embedded Compact Special features and device-specific settings are described in the following! 7.2.1 Backup and restore Program which you can use to save or restore an entire directory structure. 7.2.2 Password settings Operating Manual PMI 6 1003280-EN-01...
  • Page 22 If you select Ask for master password ..., then the system will request that the master pass- word is entered before the Control Panel opens. Timeout If an incorrect password is entered three times or no valid password is entered within the selected time, then the Control Panel is closed. Operating Manual PMI 6 1003280-EN-01...
  • Page 23 Add Password Settings to the password protected area, otherwise the password you enter will be unprotected and can be changed. Level 3: Network user Access to the network servers is controlled by a central user. Operating Manual PMI 6 1003280-EN-01...
  • Page 24: Date/Time

    Keyboard & soft keyboard Setting the keyboard layout (German or English) and setting the soft keyboard (small, large or no keyboard) 7.2.6 Network and dial-up Modify existing connections (e.g. IP address) or set new connections (PPP over Ethernet) Operating Manual PMI 6 1003280-EN-01...
  • Page 25: Regional Settings

    Regional settings Regional settings (number format, currency, time, date) 7.2.8 Storage Manager Format/partition memory 7.2.9 System Display/modify system properties (relationship between program memory/file management) 7.2.10 Edit PMI Start Edit or create the batch file PMI-Start.cmd Operating Manual PMI 6 1003280-EN-01...
  • Page 26: Taskbar And Desktop

    All files and directories are copied to the system folder \Windows on start-up. Fonts (TTF) in the folder \BOOT\Windows\Fonts\ are also registered. Tip: Memory-intensive fonts should be installed on the external Storage Card using fontreg (see Windows CE Shell commands - Pilz expansions [ 35]). 7.3.2 Batch file PMIStart.cmd PMIStart.cmd is a CE Shell command batch file, which is executed sequentially after boot-...
  • Page 27: Network Settings

    Regional settings: English (currency, date, time, numbers) User input language: English (fixed) Input language: English (keyboard) (see Regional settings [ 25]) Network: – User: pmiuser – Password: 1234 (see Password settings [ 21]) Network device name: PMI6xx (see System [ 25]) Operating Manual PMI 6 1003280-EN-01...
  • Page 28: Care And Maintenance

    Make sure the unit is switched off before cleaning it. This prevents you from accidentally triggering functions when you touch the touchscreen. Cleaning agents Only use water and washing-up liquid or window cleaner to dampen the cloth. Never use aggressive solvents or abrasive cleaning agents. Operating Manual PMI 6 1003280-EN-01...
  • Page 29: Attachment

    - Connection Manager All Modules Networking General - Extended DNS Querying and Update (DNSAPI) - NDIS Packet Capturing DLL - NDIS User-mode I/O Protocol Driver - Network Driver Architecture (NDIS) - Network Utilities (IPConfig, Ping, Route) Operating Manual PMI 6 1003280-EN-01...
  • Page 30 - Memory Mapped Files - Message Queue - Point-to-Point - Target Control Support (Shell.exe) UI based Notification Notification LED Support Power Management (Full) Serial Port Support UI Proxy for Kernel-Mode-Drivers Windows Embedded CE Driver Development Kit Support Library Operating Manual PMI 6 1003280-EN-01...
  • Page 31 Courier New Georgia Impact Lucida Sans Microsoft San Serif Segoe UI Display Tahoma Times New Roman Trebuchet MS Verdana Webdings Wingdings INFORMATION TTF formats can be post-installed (see Automatically copy to system folder (\windows) [ 26]). Operating Manual PMI 6 1003280-EN-01...
  • Page 32 - Internet Explorer Multi-Language Base API - URL Moniker Service - Windows Internet Services - XML MIME Viewer - Internet Option Control Panel - Scripting - JScript 5.8 - Script Authoring (Jscript) - VBScript 5.8 Operating Manual PMI 6 1003280-EN-01...
  • Page 33 - Software Input Panel - Software-based Input Panel (SIP) - SIP for Large Screens - SIP for Small Screens - Software-based Input Panel Drivers Windows Embedded Compact Error Reporting - Error Report Generator - Error Report Transfer Driver Operating Manual PMI 6 1003280-EN-01...
  • Page 34: Windows Ce Shell Commands

    Shows the files and subdirectories contained in a directory "ECHO [mes- Shows a message or activates/deactivates the echo sage] [on| off] " "ERASE, DEL" Deletes a file or several files "EXIT" Exits "command processor shell" Operating Manual PMI 6 1003280-EN-01...
  • Page 35: Windows Ce Shell Commands - Pilz Expansions

    Sets the title of the "command processor" window "TYPE" Shows the content of a text file or several text files Windows CE Shell commands - Pilz expansions INFORMATION You can use the command "/?" to call up the help. There you will find more information on the individual commands.
  • Page 36 Syntax: ps reboot Command used to restart the device Syntax: reboot <sec> Parameter Description <sec> Waiting period in seconds before the device is re- started regedit Command used to start the registration editor Syntax: regedit Operating Manual PMI 6 1003280-EN-01...
  • Page 37 Command used to print a screenshot or save it to file Syntax: screenshot -p <port> -d <devicename> -x <filename> -f <form- size> -o [p]ortrait [l]andscape -q [d]raft, [h]igh -s <scalefactor> -c [c]olor,[m]ono -n <copies> Parameter Description Operating Manual PMI 6 1003280-EN-01...
  • Page 38 Command used to show information on the device Syntax: ver [/d] [/a] [/hw /p /o /l /s /r /c] Parameter Description Data mode, display without description, e. g.: PMI 515 10000007 264515 Show all information Outputs the hardware version Outputs the processor type Operating Manual PMI 6 1003280-EN-01...
  • Page 39 Command used to copy files and directory structures Syntax: xcopy [ -c | -h | -y <title>] <sourcedir> <targetdir> Parameter Description Messages are suppressed Delete target directory first <SourceDir> Absolute path of the source directory <TargetDir> Absolute path of the target directory Operating Manual PMI 6 1003280-EN-01...
  • Page 40: Technical Details

    Number Connection type RJ45 RJ45 Transmission rate 1 Gbit/s 1 Gbit/s Serial interface 265607 265612 Number of RS232 interfaces Environmental data 265607 265612 Ambient temperature Temperature range 0 - 50 °C 0 - 50 °C Operating Manual PMI 6 1003280-EN-01...
  • Page 41 Mechanical data 265607 265612 Dimensions 153 mm 222 mm Height Width 216 mm 332 mm Depth 85 mm 83 mm Weight 1.740 g 2.730 g Where standards are undated, the 2014-08 latest editions shall apply. Operating Manual PMI 6 1003280-EN-01...
  • Page 42: Order Reference

    Product Product type Features Order No. PMI 607 Control Operator terminal, 800 x 480 pixel resolution, ca- 265 607 pacitive touchscreen PMI 612 Control Operator terminal, 1280 x 800 pixel resolution, 265 612 capacitive touchscreen Operating Manual PMI 6 1003280-EN-01...
  • Page 43 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland +41 62 88979-30 Mexico +43 1 7986263-0...