PMI v704e/v707e
Operator terminals
}
Operating Manual-1003980-EN-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PMI v704e and is the answer not in the manual?

Questions and answers

Summary of Contents for Pilz PMI v704e

  • Page 1 PMI v704e/v707e Operator terminals Operating Manual-1003980-EN-02...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    4.2.1 PMI v704e 4.2.2 PMI v707e Section 5 Installation Safety 5.1.1 Installation site and unit surroundings Dimensions Installing the unit Installation 5.4.1 PMI v704e 5.4.2 PMI v707e Section 6 Wiring General wiring guidelines 6.1.1 Shielding Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 4 Settings for the PASvisu server 7.1.4 Licence information 7.1.5 Exit PMI Manager Section 8 Firmware update Section 9 Care and Maintenance Cleaning the touchscreen Section 10 Technical details Section 11 Order reference 11.1 Product 11.2 Accessories Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 5: Introduction

    This describes a situation in which the product or devices could be dam- aged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import- ance. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 6: Legal Information

    The request for the source code must be received 3 years at the latest after the receipt of the relevant GPL or LPG. Irrespective of this period we will send you a complete, machine- readable copy of the source code as long as Pilz offers spares or technical support for this device.
  • Page 7: Overview

    2.1.1 Unit features Capacitive touchscreen Character set: Unicode Memory: 512 MB DDR SDRAM 2 GB Flash 1 Ethernet interface 1 USB Host interface 2.0 Type A Capacitor-buffered real-time clock Pre-installed software: – Pilz visualisation software Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 8: Front View

    Overview Front view 2.2.1 PMI v704e Fig.: Front view PMI v704e Legend [1] Touchscreen (see Technical details [ 36]) Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 9: Pmi V707E

    Fig.: Front view PMI v707e Legend [1] Touchscreen (see Technical details [ 36]) Scope of supply Operator terminal 1 clamp frame for installation 1 set of screws and connectors Projection stand in the shape of the packaging carton Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 10: Accessories

    Accessories Fig.: Top hat rail for PMI v704e Legend [1] Top hat rail for installation in the control cabinet, see order data [ NOTICE The top hat rail may only be used for PMI v704e. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 11: Safety

    - PNOZ m B0 from Version 1.0 - PNOZ m B1 from firmware Version 1.1.1 PNOZmulti Configurator from Version 10.x.x PASvisu Builder from Version 1.6.x Further information on PASvisu can be found in the PASvisu online help. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 12: Safety Regulations

    Do not position PMI close to highly flammable materials. When installing the unit within a control cabinet, you must ensure the ventilation slots are not obstructed, otherwise the unit could be damaged through overheating. Protect the unit from direct sunlight and dust. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 13: Measures To Protect Against Interference

    Avoid using chemicals close to the system. 3.3.5 Maintenance Do not use thinners or organic solvents to clean the unit and touchscreen surface. Further information on care and maintenance of the touchscreen can be found in the chapter "Care and Maintenance". Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 14: Function Description

    Function description Device properties The operator terminal has a memory in which a Pilz visualisation software is preinstalled. With the help of this software, processes can be shown on the display and directly influ- enced via the touchscreen. An Ethernet interface is available for the transfer of data, e.g.
  • Page 15: Side View

    Function description Side view 4.2.1 PMI v704e Fig.: Side view PMI v704e Legend [1] USB Host [2] Ethernet interface (100 BaseTX) [3] Supply voltage Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 16: Pmi V707E

    Function description 4.2.2 PMI v707e Fig.: Side view PMI v707e Legend [1] USB Host [2] Ethernet interface (100 BaseTX) [3] Supply voltage Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 17: Installation Safety

    Do not use chemicals close to the system. Ensure the maximum ambient and operating temperatures are not exceeded. Ensure that neither liquids nor objects can enter the unit at any time. Do not position the system close to flammable materials. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 18: Dimensions

    183 + 1 (7.205" + 0.039") h3/mm 78 + 1 (3.071" + 0.039") 125 + 1 (4.921" + 0.039") h*/t* = Dimensions without connections b2/h2* = Dimensions without press-in frame Allow extra for hardware connections! Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 19: Installing The Unit

    1 Nm – the gasket is not damaged – the mounting position is vertical (the Pilz logo has to be at the bottom) – the wall thickness is at least 2.5 mm. Operating Manual PMI v704e/v707e...
  • Page 20: Installation

    Installation Installation 5.4.1 PMI v704e Fig.: Installing PMI v704e Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 21 Installation Fig.: Installing PMI v704e with top hat rail Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 22 Installation Fig.: Strain relief for Ethernet and USB cables PMI v704e Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 23: Pmi V707E

    Installation 5.4.2 PMI v707e Fig.: Installing PMI v707e Fig.: Strain relief for Ethernet and USB cable PMI v707e Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 24: Wiring

    (e.g. RC networks). This is particularly important if these induct- ive loads are very close to the power supply or are fed from the same supply. If strong magnetic fields are present, we recommend you use a bulkhead separator, i.e. metal sheet (MU-metal). Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 25: Connecting The Unit

    The connection for the 24 V DC supply is located on the side of the housing. Fig.: Layout of supply voltage connector 1: 0 V 2: + 24 V DC UL requirement: Use a 24 VDC power supply (isolating source). Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 26: Connection Example

    GND connection is to be created to a remote point (e.g. via an USB-RS485 converter or similar), an unlimited and possibly damaging equalising current can flow over the shield. In this case, the interface should be galvanically isolated. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 27: Commissioning

    Fig.: Start screen PMI Manager After starting the PMI, you can make basic settings for the device in the PMI Manager. To do this, touch the button within 5 seconds. The interface is only available in English. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 28: Network Settings

    After starting, the following view will open where you can configure all the required network settings: Fig.: Network settings When you touch a field, a key field will open for entering the address. Fig.: Entry network settings Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 29: Configuration

    You can use a time server. To do this, touch the empty field behind "Use NTP Time Service". You can select whether you want to enter an IP address in IPv4 format or an URL (e.g. the address of the Physikalisch-Technische Bundesanstalt "ptbtime1.ptb.de"). Fig.: Use time server Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 30 Commissioning The local time will be adapted automatically as the system time. Touch the button to change the date or time. Enter the time in 24 hour format "hh:mm:ss". Fig.: Set time and date Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 31: Settings For The Pasvisu Server

    You have the option to use a local PASvisu Server. To do this, enter the IP address of PASvisu Server in IPv4 format. Default setting: IP address: 127.000.000.001 Server HTTP port: 40856 Server WS port: 40857 Fig.: Settings PASvisu Server Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 32: Licence Information

    Commissioning 7.1.4 Licence information In the sidebar, touch the button to display the licence information. Fig.: Licence information Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 33: Exit Pmi Manager

    Touch the button "Discard" to reject the changes and to start the PASvisu project. Touch the button "Cancel" to return to the settings. Further information on PASvisu can be found in the PASvisu online help. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 34: Firmware Update

    Firmware update Firmware update The firmware of the PMI v704e/v707e can be updated. An update package can be downloaded to the device from the download area on the Pilz website. The update is performed via a USB stick. If you wish to update the firmware, proceed as follows: 1.
  • Page 35: Care And Maintenance

    Make sure the unit is switched off before cleaning it. This prevents you from accidentally triggering functions when you touch the touchscreen. Cleaning agents Only use water and washing-up liquid or window cleaner to dampen the cloth. Never use aggressive solvents or abrasive cleaning agents. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 36: Technical Details

    Condensation during operation Not permitted Not permitted EN 61000-4-2, EN 61000-4-3, EN EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-6-2, EN 61000-4-6, EN 61000-6-2, EN 61000-6-4 61000-6-4 Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 37 Mechanical data 266704 266707 Dimensions Height 95 mm 142 mm Width 135 mm 200 mm Depth 36,3 mm 50,3 mm Weight 348 g 944 g Where standards are undated, the 2018-01 latest editions shall apply. Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 38: Order Reference

    PMI v707e Operator terminal, 800 x 480 pixel resolution, ca- 266 707 pacitive touchscreen 11.2 Accessories Product type Features Order no. DIN rail adapter TSH DIN top hat rail TSH 35 266 103 Operating Manual PMI v704e/v707e 1003980-EN-02...
  • Page 39 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia +45 74436332 Brazil +61 3 95600621 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...