Operation

7
Operation
When the supply voltage is switched on, the PNOZmulti safety system copies the configur-
ation from the chip card.
The LEDs "POWER", "DIAG", "FAULT", "IFAULT" and "OFAULT" will light up on the base
unit.
The expansion module PNOZ mc4p is configured and started automatically. The LEDs
"MS" and "NS" display the status of the PNOZ mc4p on DeviceNet.
If the expansion module PNOZ mc4p does not receive a configuration from the base unit
for a period of 30 s, the fieldbus module PNOZ mc4p connects to DeviceNet and "Online"
status is displayed on DeviceNet. The "MS" LED flashes red.
7.1

Messages

Legend
LED
NS
Green
Green
Red
Red
MS
Green
Green
Red
Red
Operating Manual PNOZ mc4p
21054-EN-05
LED on
LED flashes
LED off
Meaning
PNOZ mc4p in "Link OK, Online, Connected" status
PNOZ mc4p in "Online, Not connected" status
PNOZ mc4p detects "Critical link failure"
Time monitoring ("Connection Timeout") has expired.
No supply voltage or offline
PNOZ mc4p in "Device Operational" status
Configuration error; size of data does not correspond to the configuration
PNOZ mc4p detects non-recoverable error
PNOZ mc4p detects recoverable error ("Minor Fault").
No supply voltage on PNOZ mc4p
Remedy: Make sure that the fieldbus module PNOZ mc4p is connected to
the base unit.