Wire Feed Speed (WFS) unit – enables change of the
displayed WFS unit:
CE (factory default) - m/min;
US - in/min.
Hot Start - percentage regulation of growth nominal current
value during arc start. It cause temporary rise up of output
current which makes ignition of the electrode easier.
Factory default: 0.0
Regulation range: from -10.0 to +10.0.
This parameter is only for SMAW.
Arc Force - temporary increased of the output current to
prevent sticking of the electrode in order to facilitate welding
process.
Lower values will provided less short circuit current and a
softer arc. Higher settings will provided a higher short circuit
current, more forceful arc and possibly more spatter.
Factory default: 5.0
Regulation range: from 0.0 to +10.0
Restore to Factory Settings – it allows to restore the
factory settings.
View Software version – used for viewing the software
version on user interface.
First view shows the effect after getting access to the Soft
menu.
Second view shows the effect after getting access to
parameter edit.
Cooler – option is available when cooler is connected.
This function allows following cooler modes:
FILL – Filling.
AUTO – Automatic mode.
On – Cooler on in the continuous mode.
Off – Cooler off.
Refer cooler instruction manual for more details.