Introduction
The Split Unit Gateway forms the interface between the ABB-free@home
conditioning devices, so-called split units, from a wide range of manufacturers. The device
converts the ABB-free@home
Split Unit.
The Split Unit Gateway is installed in close proximity (maximum distance of 2 metres) to the
Split Unit. The transmission unit of the enclosed cable is glued directly on the receiving unit of
the Split Unit. The air-conditioning device then no longer receives commands from a remote
control, but can be operated via any ABB-free@home
The following functions are provided:
Switch-on / switch-off
■
Specifying the set-point temperature including parameterizable set-point temperature limit
■
Setting the operating Mode (Automatic, Heating, Cooling, Ventilation, Drying)
■
Control of fan speed level
■
Slat adjustment horizontal and vertical
■
Activation of silent mode
■
Notice
–
–
–
Basic information about system integration is contained in the system manual. It
is available for downloading at https://abb.com/freeathome.
Product manual 9AKK107680A2816
®
telegrams into infrared commands and transmits them to the
Not all Split Units support all functions. Only functions that the respective
Split Unit supports are enabled in the user interface.
Example: Some Split Units do not support all operating modes.
The Split Unit Gateway supports 3 fan speed levels and automatic. To the
extent a Split Unit supports fan speed levels, they are mapped accordingly.
Example: A Split Unit has 5 fan speed levels. Then levels 1/3/5 are mapped
to 1/2/3 and levels 2+4 cannot be activated.
The communication to the Split Unit is unidirectional. This means that while
the Split Unit Gateway sends commands to the Split Unit, it does not receive
a status message from it. Therefore, if a Split Unit is operated in parallel with
a remote control, the status of the gateway can deviate from the actual
status of the Split Unit. The same applies when a Split Unit is not ready to
receive. Then, if necessary, a command may have to be sent via ABB-
free@home
®
so that the status values are again being synchronized.
Setup and function
®
system and air-
®
sensors or via the visualization.