ABB free@home SUG-F-1.1 Product Manual page 29

Split unit gateway
Table of Contents

Advertisement

Unit Gateway, the highest permitted value is sent to the Split Unit. The status value is adjusted
accordingly.
[8] Setting the minimum setpoint temperature via the -/+ buttons. This parameter fixes the limits for the
setpoint temperature. If a temperature value below the minimum setpoint temperature is sent to the Split
Unit Gateway, the lowest permitted value is sent to the Split Unit. The status value is adjusted
accordingly.
Notice
It must be checked whether the Split Unit supports the desired temperature
range. This is available in the documentation of the Split Unit manufacturer.
[9] Specification whether the outdoor unit of the Split Unit is to be set into a low-noise operating mode. The
precise behaviour of the Split Unit in this mode is available in the Split Unit product manual.
Notice
It must be checked whether the silent mode is supported by the Split Unit.
[10] Specification whether the infrared commands are always to be sent. If the Split Unit is operated in parallel
with a remote control, the status of the Split Unit can deviate from the status of the gateway. To ensure
that the Split Unit always takes on the correct status, this parameter must be activated. It can, however,
lead to an increase in acknowledgment tones of the Split Unit Gateway.
Selecting remote control
The model of the remote control can be selected and allocated in the list view of the device via
the "Remote control" button. This selection window displays the manufacturer of the Split Unit
and the model of the remote control. Select the appropriate specifications and confirm them with
a tick.
Fig. 13:
Select the remote control
 
Product manual 9AKK107680A2816
Commissioning
│29