ABB ARG600 User Manual

ABB ARG600 User Manual

Wireless gateway ansi single sim variants
Hide thumbs Also See for ARG600:

Advertisement

Quick Links

Wireless Gateway
ARG600 ANSI Single SIM Variants
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB ARG600

  • Page 1 — Wireless Gateway ARG600 ANSI Single SIM Variants User Manual...
  • Page 3 Document ID: 1MRS758865 Issued: 2019-04-24 Revision: B Product version: 3.4.7 © Copyright 2019 ABB. All rights reserved...
  • Page 4 Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
  • Page 5 ABB is not liable for any such damages and/or losses.
  • Page 6 Safety information Dangerous voltages can occur on the connectors, even though the auxiliary voltage has been disconnected. Non-observance can result in death, personal injury or substantial property damage. Only a competent electrician is allowed to carry out the electrical installation. National and local electrical safety regulations must always be followed.
  • Page 7 handling of the devices is appropriate. This also applies to the maintenance of the products.
  • Page 9: Table Of Contents

    Product documentation................3 Product documentation set..............3 Document revision history..............3 Related documentation................4 Symbols and conventions.................4 Symbols....................4 Document conventions................ 5 Section 2 ARG600 overview..............7 Overview....................7 Physical interfaces..................8 Front panel...................8 Back panel..................10 Side panel..................11 DIN rail mounting..................13 Product information label ............... 13 Firmware version..................
  • Page 10 Saving configuration profiles..............28 Section 7 Service configuration............31 Configuring services................31 Service parameters.................31 Section 8 Troubleshooting..............35 Common troubleshooting issues............35 Viewing the system log................36 Section 9 Technical data..............37 Section 10 Glossary................43 ARG600 ANSI Single SIM Variants User Manual...
  • Page 11: Section 1 Introduction

    The personnel is expected to be familiar with basic working principles of Internet technology. Product documentation 1.3.1 Product documentation set Product series- and product-specific manuals can be downloaded from the ABB Web site http://www.abb.com/substationautomation. 1.3.2 Document revision history Document revision/date...
  • Page 12: Related Documentation

    3G/LTE Wireless Gateway firmware Updating firmware of Wireless Gateway 1MRS758451 update Technical Note devices Product series- and product-specific manuals can be downloaded from the ABB Web site http://www.abb.com/substationautomation. Symbols and conventions 1.4.1 Symbols The electrical warning icon indicates the presence of a hazard which could result in electrical shock.
  • Page 13: Document Conventions

    Parameter names are shown in italics. The function can be enabled and disabled with the Operation setting. • Parameter values are indicated with quotation marks. The corresponding parameter values are "On" and "Off". ARG600 ANSI Single SIM Variants User Manual...
  • Page 15: Section 2 Arg600 Overview

    SCADA systems. Wireless Gateway ARG600 is a member of ABB’s Arctic product family and part of its 600 Wireless Gateway product series. By using Wireless Gateway ARG600, Ethernet and serial devices can be attached to a TCP/IP based control system.
  • Page 16: Physical Interfaces

    1 Power supply 12...48 VDC 2 Console/serial port 3 Application serial ports 4 LAN/WAN port 5 Power switch 6 Console/serial port switch 7 DIP switches Power supply connector The device has a VDC power supply connector. ARG600 ANSI Single SIM Variants User Manual...
  • Page 17 The DIP switches select an application port (RS2) mode and settings (RS-232 or RS-485). By default, all DIP switches are set to the 0 position (RS-232 mode). DIP switches 2...4 apply only when DIP switch 1 is set to differential mode (RS-485/RS-422). ARG600 ANSI Single SIM Variants User Manual...
  • Page 18: Back Panel

    The device has an RJ-45 connector for 10/100 Mbps Ethernet connection. The maximum length of the Ethernet cable is 100 m. 2.2.2 Back panel The device has an antenna connector and a slot for a SIM card on the back panel. ARG600 ANSI Single SIM Variants User Manual...
  • Page 19: Side Panel

    The ten LEDs on the side panel of the device indicate the status of the device. Only five of them are connected. The LEDs are numbered 1...10 starting from the rear panel side. ARG600 ANSI Single SIM Variants User Manual...
  • Page 20 VPN connection is disabled Power/Error Operating power is turned on Operating power is turned off Function Device is starting Flashing Device is operating normally Device is not operational Table continues on next page ARG600 ANSI Single SIM Variants User Manual...
  • Page 21: Din Rail Mounting

    Ethernet MAC address. Firmware version The device's firmware version is visible on the welcome page (System/Welcome Page), which is displayed after logging in to the device. For firmware updates, contact ABB's technical customer support. ARG600 ANSI Single SIM Variants User Manual...
  • Page 23: Section 3 Getting Started

    Ethernet connection goes down, the traffic is automatically switched to mobile WAN (secondary connection) and back when the Ethernet interface comes up again. Logging in Configure the computer to use the same IP address space as the device. ARG600 ANSI Single SIM Variants User Manual...
  • Page 24: User Interface

    Click Submit to save the settings. If the functional mode of the Ethernet port is set to "WAN" or "VLAN", the following details must be noted. Before changing the Ethernet port mode to "WAN", the firewall ARG600 ANSI Single SIM Variants User Manual...
  • Page 25: Configuring Mobile Wan

    Interface to Mobile WAN or Ethernet WAN, whichever is not selected as the default gateway. If the primary WAN interface comes down, the device automatically switches the default route to the backup WAN interface. Click Submit to save the settings. Restart the device. ARG600 ANSI Single SIM Variants User Manual...
  • Page 27: Section 4 Network Configuration

    The Connectivity Monitor keeps checking the connection to the given remote host to determine the network status. If the ping does not get an answer within a given time window, it informs the WAN switch logic to try the secondary interface. ARG600 ANSI Single SIM Variants User Manual...
  • Page 28: Configuring The Mobile Wan Interface

    In the left pane, click Network WAN Failover. Set WAN Default Route to Yes. This setting enables the use of the Ethernet WAN or the Mobile WAN as the default route interface. Set the value of Mobile WAN On Demand. ARG600 ANSI Single SIM Variants User Manual...
  • Page 29: Routing Parameters

    If both the wireless and Ethernet WAN interfaces have to be up all the time, select No. Click Submit to save the settings. Restart the device. Routing parameters The device has multiple configuration options that define routing. ARG600 ANSI Single SIM Variants User Manual...
  • Page 30: Configuring The Network Monitor

    OpenVPN. See Default route OpenVPN application note. Configuring the network monitor The network monitor detects Internet connectivity drops by sending ping packets to designated targets. Its use is recommended. ARG600 ANSI Single SIM Variants User Manual...
  • Page 31: Configuring Dns Proxy

    In the left pane, under System, click Status to view network status information. In the left pane, under Tools, click Modem Info to view the status of the wireless modem. Check if the cellular LED is flashing, indicating network traffic. ARG600 ANSI Single SIM Variants User Manual...
  • Page 33: Section 5 Serial Port Configuration

    Because of the transparent communication, any protocols can be used in actual communication between nodes.Serial gateway configuration depends on used protocols. ARG600 ANSI Single SIM Variants User Manual...
  • Page 35: Section 6 Additional System Configuration

    In the “Manual” mode, enter the time and date in the Time and Date fields, respectively. Clicking Copy PC changes the device’s time and date settings to match the connected PC. This requires JavaScript support from the browser. Click Submit to save the settings. ARG600 ANSI Single SIM Variants User Manual...
  • Page 36: Restoring Factory Default Settings

    Select a profile to clone. Selecting Last Boot allows saving the configuration in use when the device was booted the previous time. Type a name for the profile. Click Submit to save the profile. ARG600 ANSI Single SIM Variants User Manual...
  • Page 37 Section 6 1MRS758865 B Additional system configuration It is possible to clone, export, and import profiles in the same view. ARG600 ANSI Single SIM Variants User Manual...
  • Page 39: Section 7 Service Configuration

    Selects which SSH protocol versions are enabled in SSH Server. It is SSH1, SSH2 version recommended to allow only SSH protocol version 2 (SSH2) to be used. SSH public SSH Public keys can be added for remote logins with SSHkeys. keys ARG600 ANSI Single SIM Variants User Manual...
  • Page 40 Selects the supported dyndns service provider service provider DynDNS client Defines how often (in seconds) the device's IP is checked update interval DynDNS Arctic name reported to service, for example, host name hostname Table continues on next page ARG600 ANSI Single SIM Variants User Manual...
  • Page 41 Server IP address and the port the server listens. If no value is given, address, server the value is 10000. port SSH Settings (Only needed for SSH protocol) Table continues on next page ARG600 ANSI Single SIM Variants User Manual...
  • Page 42 Allow remote Enables remote management by Patrol server No, Yes management Allow LAN Allows periodical local network scan for ABB devices. Currently, the No, Yes device scan supported device is RIO600. ARG600 ANSI Single SIM Variants User Manual...
  • Page 43: Section 8 Troubleshooting

    4. Check that Use DNS Proxy is set to “Yes” in the Services/Common screen. 5. Configure network settings on laptop to use the device's Ethernet LAN address as gateway and DNS server. With these settings, the Internet should be accessible on the laptop. ARG600 ANSI Single SIM Variants User Manual...
  • Page 44: Viewing The System Log

    Section 8 1MRS758865 B Troubleshooting Viewing the system log In the left pane, under Tools, select System Log. If necessary, refresh the system log with the Web browser’s reload or refresh button. ARG600 ANSI Single SIM Variants User Manual...
  • Page 45: Section 9 Technical Data

    5...85% RH (non condensing) Protection class IP30 Table 12: Supported protocols Master protocol Slave protocol IEC 60870-5-104 IEC 60870-5-101 Modbus TCP Modbus RTU/ASCII TCP/IP, UDP/IP (DNP3) Serial gateway - serial port data stream (such as DNP3) ARG600 ANSI Single SIM Variants User Manual...
  • Page 46 Parity: None, Even, Odd Flow control: None, RTS/CTS Protection: 15 kV ESD and short circuit Table 14: Variant codes Variant Cellular operator FCC ID ARG600A1270NA AT&T (operator approved) N7NMC7355 ARG600A1290NA North America and Mexico N7NMC7355 generic ARG600 ANSI Single SIM Variants User Manual...
  • Page 47 WCDMA 2100 Band 2 1850...1910 MHz 1930...1990 MHz WCDMA 1900 Band 4 1710...1755 MHz 2110...2155 MHz AWS 1700/2100 Band 5 824...849 MHz 869...894 MHz WCDMA 850 Band 8 880...915 MHz 925...960 MHz WCDMA 900 ARG600 ANSI Single SIM Variants User Manual...
  • Page 48 61850-3 (Edition 2.0 electromagnetic field EN 61000-4-3 (2006-02) 2013-12) Electrical fast transient (EFT) EN 61000-4-4 (2012-04) Surge EN 61000-4-5 (2005-11) Conducted radiofrequency electromagnetic field EN 61000-4-6 (2008-10) Power frequency magnetic field EN 61000-4-8 (2009-09) ARG600 ANSI Single SIM Variants User Manual...
  • Page 49 1MRS758865 B Technical data Table 22: RoHS and REACH compliancy Description Reference Directive RoHS directive 2002/95/EC REACH directive 2006/1907/EC Table 23: FCC compliancy Description Reference Standard FCC 47 CFR FCC Part 15 ANSI C63.4-2014 ARG600 ANSI Single SIM Variants User Manual...
  • Page 51: Section 10 Glossary

    RJ-45 Galvanic connector type RS-232 Serial interface standard RS-422 Serial communication standard (EIA–422) RS-485 Serial link according to EIA standard RS485 Ready to send SCADA Supervision, control and data acquisition Subscriber identity module ARG600 ANSI Single SIM Variants User Manual...
  • Page 52 Section 10 1MRS758865 B Glossary SNTP Simple Network Time Protocol Transmission Control Protocol TCP/IP Transmission Control Protocol/Internet Protocol Virtual Private Network Wide area network ARG600 ANSI Single SIM Variants User Manual...
  • Page 56 Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone +358 10 22 11 ABB Inc. 655 Century Point Lake Mary, FL 32746, USA Phone +1 407 732 2000 +1 407 732 2245 www.abb.com/mediumvoltage www.abb.com/substationautomation © Copyright 2019 ABB. All rights reserved.

Table of Contents