13. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart (All white frame) (Note2)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note1: This adjustment should be carried out upon completion of "Auto
White Balance Standard Data Input".
Note2: Perform "11. Picture Frame Setting (All White Frame)" before
this adjustment.
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
4
6
01
0D
5
6
02
6
0
03
1E
7
1
Note6: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
00
2
0
03
00
3
0
01
00
4
Procedure
Check that the whole of the screen
is white. If not, perform "11.
Picture Frame Setting (All White
Frame)".
Set the data.
Wait for more than 6 sec.
Set the data, and press PAUSE
button.
Check that the data changes to
"01" within 20 sec. (Note6)
Set the data.
Check that the display data
(Note5) satisfies the specified
value.
Procedure
Set the data, and press PAUSE
button.
Set the data.
Set the data.
Perform "Auto White Balance
Adjustment".

14. Auto White Balance Adjustment

Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Filter
Adjustment Page
Adjustment Address
Note1: This adjustment should be carried out upon completion of "Auto
White Balance Standard Data Input".
Note2: Perform "11. Picture Frame Setting (All White Frame)" before
this adjustment.
Note3: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
1
2
3
0
01
4
0
10
5
F
44
6
F
45
7
F
46
8
F
47
9
6
01
10
6
01
11
6
02
Note4: The adjustment data will be automatically input to page: F, address:
32 to 35 and to page: 14, address: F4 to FF.
Processing after Completing Adjustments:
Order Page Address Data
1
0
10
2
6
01
3
0
01
4
6-31
DCR-HC65
Clear chart (All white frame) (Note2)
Filter C14 for color temperature
correction
F
14 (Note3)
32 to 35, 44 to 47
F4 to FF
Procedure
Check that the whole of the screen
is white. If not, perform "11.
Picture Frame Setting (All White
Frame)".
Place the C14 filter for color
temperature correction on the lens.
01
Set the data.
00
Set the data.
2D
Set the data, and press PAUSE
button.
40
Set the data, and press PAUSE
button.
58
Set the data, and press PAUSE
button.
80
Set the data, and press PAUSE
button.
47
Set the data, and press PAUSE
button.
45
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Procedure
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
Perform "White Balance Check".