Service Mode; Setting The Test Mode; Emergence Memory Address (Camera Section); Emg Code (Emergency Code) - Sony DCR-HC65 Adjusting Manual

Hide thumbs Also See for DCR-HC65:
Table of Contents

Advertisement

4-3.

SERVICE MODE

Note: Before performing the adjustments, check the data of page: 0,
address: 10 is "00". If not, set data: 00 to this address.

1. Setting the Test Mode

Page A
Address 10
Data
00
Normal
01
Forced camera power ON (CAMERA-TAPE mode)
02
Forced VTR power ON (PLAY/EDIT mode)
03
Forced camera + VTR power ON
05
Forced memory power ON (CAMERA-MEMORY mode)
• Before setting the data , select page: 0, address: 01, and set data: 01.
• For page A, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander.
Select page: 0, address: 01, and set data: 00.

2. Emergence Memory Address (Camera section)

Page 19
Address 87 to 8A
Note: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to "00".
Address
87
EMG code when first error occurs
88
EMG code when second error occurs
89
EMG code when third error occurs
8A
EMG code when last error occurs

2-1. EMG Code (Emergency Code)

Codes corresponding to the errors which occur are written in 19
page, addresses 87 to 8A.. The type of error indicated by the code
are shown in the following table.
Code
Emergency Type
00
No error
Note: After completing adjustments, be sure to initialize the data of
addresses 87 to 8A to "00".
Initializing method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 0, address: 10, and set data: 00.
3)
Select page: 6, address: 01, set data: FD and press the PAUSE
button.
4)
Check that the data of page: 6, address: 02 is "01".
5)
Select page: 6, address: 01, set data: 00 and press the PAUSE
button.
6)
Select page: 0, address: 01, and set data: 00.
Function
Contents

3. Emergence Memory Address (Mechanism section)

Page C
Address
F4
EMG code when first error occurs
Upper: MSW code when shift starts when first
F6
error occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
F7
occurs
F8
EMG code when second error occurs
Upper: MSW code when shift starts when second
FA
error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
FB
occurs
FC
EMG code when last error occurs
Upper: MSW code when shift starts when last error
FE
occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
FF
occurs
When no error occurs in this unit, data "00" is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(F4 to F7). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(F8 to FB). Finally, when the last error occurs, the data corresponding
to the error is written in the last emergency address (FC to FF).
Note: After completing adjustments, be sure to initialize the data of
addresses F4 to FF to "00".
Initializing method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 37, and press the PAUSE
button.
3)
Check that the data of page:3, address:02 is "00".
4)
Select page: 0, address: 01, and set data: 00.
3-1. EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in
addresses F4, F8 and FC. The type of error indicated by the code
are shown in the following table.
Code
00
No error
10
Loading motor emergency during loading
11
Loading motor emergency during unloading
22
T reel emergency during normal rotation
23
S reel emergency during normal rotation
T reel emergency (Short circuit between S reel
24
terminal and T reel terminal)
30
FG emergency at the start up of the capstan
40
FG emergency at the start up of the drum
42
FG emergency during normal rotation of the drum
6-55
DCR-HC65
Address F4 to FF
Contents
Emergency Type

Advertisement