ERROR DESCRIPTION
Hazardous power voltage: power circuit fault
Current detected in pilot arc circuit during
cutting
Electrode spent
Alignment error between the firmware ver-
sions of: power source, gas console, CNC in-
terface module; or, error during power source
auto-upgrade phase
Mains voltage outside specifications
Gas pipe emptying not completed or pressu-
re high in a gas supply channel
Gas console not connected to power source
No connection between the gas console
PGC-3 and PGC-2 or APGC-1 and APGC-2
Detected current, with arc off, on IGBT2
module
Current over range measurement on IGBT2
module during cutting
4.3 DESCRIPTION OF AUTOMATIC GAS CONSOLE
PANEL (FIG. 22)
The front panel of the automatic gas console features a
multifunction LED defining its status.
In particular:
Phase
LED colour
Off
Power source
Red steady
switch-on
Red/Green
alternated
Red/Green
alternated
slow
Fully operating
Green steady
CODE
Err 40
Err 49
Err 55
Err 58
Err 67
Err 79
Err 81
Err 82
Err 31
Err 36
Description
No power to internal
electronic board
Problems with micro-
processor of internal
electronic board
Waiting for commu-
nication with power
source
No communication
with power source
Regular operation
POSSIBLE SOLUTION
Contact the CEBORA assistance service.
Contact the CEBORA assistance service.
Replace the electrode and/or nozzle. Make sure the con-
sumables are correctly fitted depending on the type of job.
Also check the correctness of the cutting gas.
Contact the CEBORA assistance service.
Check the fuse of the switchboard to which the power
source mains wire is connected. If the problem continues,
contact the CEBORA assistance service.
Check the consumables parts or reduce the supply pres-
sure.
Contact the CEBORA assistance service.
Check the connection between the PGC-3 module or
APGC-1 module (top one) and the PGC-2 module or
APGC-2 module (bottom one)
Contact the CEBORA assistance service.
Contact the CEBORA assistance service.
A=multifunction LED
To manage the automatic gas console (configuration of
the cutting parameters and setting the RUN status) the
remote panel art. 460 must be connected. Make reference
to the instruction manual of this article for a description of
operation.
With the CAN digital interface open between the panto-
graph/robot and the power source, and in the absence of
art. art.460, a specific application will be required on the
control.