Summary of Contents for 3M UniPresser 3M710

  • Page 1 3M710 UniPresser for 25-Pair Modular Splicing Instructions April 2001 78-8125-3042-2-B...
  • Page 2: Table Of Contents

    Table of Contents Parts and Nomenclature .........2 Field Maintenance Kit .
  • Page 3: Parts And Nomenclature

    ™ 3M710-UT25A Uni-Presser Parts and Nomenclature (for Splicing 3M710 25 Pair Connectors) Body “T” Bar Figure 1 Figure 3 Figure 2 Component Parts 1. Handle Retaining Clip (fig. 1 & 2) 8. ”L” Clip Module (fig. 1) 2. Vertical Side Posts (fig. 1) 9.
  • Page 4: Field Maintenance Kit

    ™ 3M710-UMK25A Field Maintenance Kit Figure 4 1. Segmented Blade 6. Cleaning Brush 2. Error Tester Tool 7. Hex Screws and Washers 3. Bridge Module Support 8. Lubricating Grease 4. Bottomless Splice Module Support 9. Thumb Screws 5. Hex Wrench 10.
  • Page 5: Straight Splicing Technique

    Straight Splice Basic Technique for Straight Splicing 3M ™ 3M710 25-Pair Modules 1. Set group holders (fig. 1 #12) 38mm (1 1/2”) 2. To disengage the “T” bar from the locked above the position of the cable units to be spliced.
  • Page 6 7. Check for wire color code dressing errors with 8. Spread the conductors evenly to each side of the error tester (fig. 4 #2). With tester to the left, the “T” bar without pulling or distributing the between the vertical posts all tip conductors are conductors position in the index strip.
  • Page 7 13. Insert a module body between the vertical 14. Position the “T” bar upright above the module side posts above the index strip. Push down on the body between the vertical side posts. Apply down- module body to lightly engage the index strip. ward pressure to the “T”...
  • Page 8 18. With the “T” bar in contact with the module 19. With the conductors seated and cut, return the body, pull the handle all the way down until it hits handle to the upright and engage it firm within the the stop position.
  • Page 9: Half-Tap Splicing Technique

    Half-Tap Splicing Basic Technique for Half-Tap Splicing 3M ™ 3M710 25-Pair Modules 23. Prepare the sheath opening, 24. Fit an index strip to the 25. Check for wire dressing allowing additional slack to the Unipresser. Select a “trough” errors with an error tester. (fig. 4 “through”...
  • Page 10: Bridge Splicing Technique

    This sticky tape is positioned against the removed conductor ends as the cover is snapped onto the module. Bridge Splicing Basic Technique for Bridge Splicing 3M ™ 3M710 25-Pair Modules 33. Position a 3M710 red bridge 34.
  • Page 11: Bottomless Splicing Technique

    Use a Bridge Splice Presser Tool along the length of the module to securely seat the bridge and contacts. Bottomless Splicing Basic Technique for Bottomless Splicing 3M ™ 3M710 25-Pair Modules 39. Position a 3M710 bottomless 40. Position a straight/half-tap 41.
  • Page 12: Uni-Presser Blade Replacement

    ™ Uni-Presser Blade Replacement Old Blade Removal With the “T” bar in the “Up” With the”T” bar in the open position, use the hex nut wrench position loosen two (2) screws (fig. 4 #5) to remove the four (fig.3 #3) on the front cover of (4) screws (fig.
  • Page 13 New Blade Adjustment Install an index strip for blade With the “T” bar in the up posi- Engage the index strip by posi- adjustment. tion finger tighten the two (2) out- tioning the handle in the down side screws (fig. 2 #3) at the rear position.
  • Page 14 • Completely portable, excellent for splicing in areas where space and tool function is critical such as in aerial splicing or small footway boxes 3M™ 710 Uni-Presser 25-Pair ™ Insertion Cutting Tool ™ Bridge to Splicer Presser Cutter Presser Tool...
  • Page 15 ™ Bridge Removal Tool ™ Half Tap Cover ™ Cap Removal Tool 3M710 BRT10A 3M710-HTC-25 3M710-CRT10 (80611047780) (80611047947) (80611036395) • For removing bridge • Used to cover and seal the • For removal of caps from connectors from the removed half-tap cable pairs connector modules to rearrange connector module following the cutting operation...
  • Page 16 MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product.