JRC JMA-3400 Series Instruction Manual page 257

Hide thumbs Also See for JMA-3400 Series:
Table of Contents

Advertisement

Alarm Name
*Screen notation
Area1(Approach)
Area1(Secession)
Area1(Out of Range)
Area2(Approach)
Area2(Secession)
Area2(Out of Range)
TT(CPA/TCPA)
TT(New Target)
TT(Lost)
Dragging anchor
GPS(Error)
GPS(HDOP)
TM Reset
No Heading Data
On Preheating
Short Interval
Error Occurring
Max Point
File Not Found
USB Memory Not Set
SD Memory Not Set
File Read Error
File Write Error
Not Enough Space
Format Error
Num of files Over
File Erase Error
TT(Max Target)
Unsetting
Invalid Data
Chapter 10 MAINTENANCE AND CHECK
Class
Echo in area1.
Alarm
No echo in area1.
Alarm
Rectangle area 1 is out of range.
Alarm
Creation of area 1 is out of range.
Echo in area2.
Alarm
No echo in area2.
Alarm
Rectangle area 2 is out of range.
Alarm
Creation of area 2 is out of range.
TT is changed to a dangerous ship
Alarm
TT is automatically acquired.
Alarm
TT is lost.
Alarm
The ship has left the dragging anchor monitoring area.
Alarm
Failed to set GPS.
Status
Caution Received excessive HDOP value beyond the setting.
For TM, the own ship position is out of 40% of the radius of
Status
PPI.
Cannot function because own ship heading is not available
-
Operations for specifying TT
Status
acquisition/numerical display
-
Changing to TM
-
Changing to N Up/C Up
Transmission operation during preheating
Status
Transmission operation in the interval of 1 second or less
Status
between standby and transmission
Transmission operation during prohibition of
Status
transmission caused by scanner error
Exceeded the maximum number of marks.
Status
File does not exist.
Status
USB memory does not exist.
Status
SD memory does not exist.
Status
Caution Failed to load the file.
Caution Failed to write the file.
Insufficient capacity.
Status
Caution Failed to format.
Writing data to the USB memory in which the number of the
Caution
file has reached to the maximum.
Caution Failed to delete the file.
Manually acquired when the number of acquisitions
reached maximum.
Detected when DSP tries to acquire 11 targets or more.
Status
DSP notifies the maximum target alarm occurrence of
automatic acquisition tot the TT process task, then the TT
process task notifies it to the alarm task.
Zone creation operations for guard zone = Off.
EBL bearing setting while EBL is off.
Floating setting while EBL/VRM is off.
Status
VRM range setting while VRM is off.
Manual tuning setting while automatic tuning is on.
AIS operations while AIS function is off.
TT operations while TT function is off.
Cannot function due to invalid value
-
Invalid code is input for the code input screen
Status
Description
209

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jma-3404Jma-3406Jma-3411-4Jma-3411-6

Table of Contents