Summary of Contents for Minebea Intec Puro EF-IN P
Page 1
Operating Instructions Weight indicator Puro® 98628-000-62 Edition 1.0.0 11/27/2019 Checked on the basis of Puro® scale with software version 2.89 Minebea Intec Bovenden GmbH & Co. KG, Leinetal 2, 37120 Bovenden, Germany Phone: +49.551.309.83.0 Fax: +49.551.309.83.190...
Page 2
Any information in this document is subject to change without notice and does not represent a commitment on the part of Minebea Intec unless legally prescribed. This product should only be operated/installed by trained and qualified personnel. In correspondence concerning this product, the type, name, and release number/serial number as well as all license numbers relating to the product have to be cited.
WARNING indicates that death or severe, irreversible injury may occur if appropriate safety measures are not observed. Take the corresponding safety precautions. CAUTION Warning of personal injury. CAUTION indicates that minor, reversible injury may occur if appropriate safety measures are not observed. Take the corresponding safety precautions. Minebea Intec EN-3...
Page 6
Warning of damage to property and/or the environment. NOTICE indicates that damage to property and/or the environment may occur if appropriate safety measures are not observed. Take the corresponding safety precautions. Note: User tips, useful information, and notes. EN-4 Minebea Intec...
If there are grounds for a complaint, this must be brought to the attention of the delivery company immediately. A Minebea Intec sales or service point must be informed. Visit our website http://www.puroscales.com to get in contact.
Perform visual inspection. Before operational startup as well as after storage or transport, inspect the product visually for signs of mechanical damage. The product may not be put into operation if it has visible damage and/or is defective. EN-6 Minebea Intec...
For maximum operating time, the battery should be charged at room temperature. During battery operation, the battery symbol indicates the battery charge level remaining. The indicator will automatically turn off when the batteries are empty. Minebea Intec EN-7...
Connection of an analog Puro® platform, or a commercially available strain-gauge load cell. Turn the device off and disconnect it from power supply. 2. Turn the device upside down. 3. Remove the four rubber plugs at the rear side. EN-8 Minebea Intec...
A printer can be connected to the printer port on the side of the device. Mounting bracket Align the mounting bracket over the threaded holes in the side of the indicator and install the knobs. Adjust the indicator to the desired angle and tighten the knobs. Minebea Intec EN-9...
10 11 Item Description Item Description Busy Low Average Piece Weight Plus symbol Low Sample Weight Minus symbol Data transfer Zero-setting Weight unit Counting Battery charge Weighing Warning symbol Checkweighing Printer Icon Totalizing NET, Preset Tare, Gross EN-10 Minebea Intec...
Page 13
(when the weight or tion. value to the selected scale is off). display the COM ports if AUTO- Set zero (when accumulated PRINT is set to off. scale is on). information. Secondary Menu Mode Unit Function Minebea Intec EN-11...
Page 14
Aborts the cali- items. play and advances to bration in pro- Decrement the the next available gress. digit. setting. Advances to Advances to the next the previous menu or item. digit in input Increment the digit. process. EN-12 Minebea Intec...
The application names are displayed every 2 seconds until the button is Mode released. If the button is released, the displayed application is selected and starts. Mode Possible applications are: [WEIGHT] normal weighing mode [COUNT] count mode Minebea Intec EN-13...
To select the weighing mode, press and hold the button until [WEIGHT] is Mode displayed with application icon appear at bottom of the screen. Release the button. The application is activated. [0.000] is displayed. 2. Place container on the scale (in this example, 0.598 kg). EN-14 Minebea Intec...
Page 17
Unit displayed, when these units are activated in menu before. [kg / g / lb /oz / lb:oz]. Release the button to select. Possible units are: gram kilogram [kg] pound [lb] ounce [oz] pound-ounces [lb:oz] Minebea Intec EN-15...
7. Press the (Yes) button to confirm reference sample quantity. 8. If the pan is empty, then [PUT.PW] (put reference) is shown on the display. Put the desired reference quantity on the pan and go on at step 7. EN-16 Minebea Intec...
Page 19
10. Counting is initialized. On the display, the actual number of pieces is shown: [20 pcs]for example. 11. Replace the reference sample with the test sample. The display shows the quantity of the sample count. 12. Press the button briefly. Mode Minebea Intec EN-17...
The different check modes must be activated prior via menu (see Chapter 6.2.1). 5.2.3.1 Check Weighing Mode Compare the weight of items to a targeted weight range. Example: The required target weighing range is between 1 kg (low limit) to 1.1 kg (high limit) EN-18 Minebea Intec...
Page 21
5. Press the (No) button to edit the value. Unit The first digit is blinking [_00.000]. 6. Press the (Yes) button to accept and highlight the next digit (or press the Menu (exit) button to go back one digit). Minebea Intec EN-19...
Page 22
The Display will show the high limit value with all digit blinking [001.100] (in this example, 1.100 kg). 11. Press the (Yes) button to accept high limit value. In case the check limit values are wrongly set, [LIM.ERR] (limit error) will be displayed briefly followed by [CLR.LIM] (clear limit). EN-20 Minebea Intec...
Page 23
1,100 kg), press the button briefly at anytime during Mode check weighing process. The scale displays the low limit value with yellow LED light briefly and the high limit value with red LED light briefly. Minebea Intec EN-21...
Page 24
(No) button (decrement) to toggle the choices [10, 20, 50, 100, Unit 200]. 5. Press the (Yes) button to confirm reference sample quantity. If the pan is empty [PUT.PW] (put piece weight) is shown on the display. EN-22 Minebea Intec...
Page 25
(Yes) button to set the low limit. The Display will show stored low limit with all digit blinking [000000] (in this example, 0 pcs). 10. Press the (No) button to edit the value. Unit The first digit is blinking [ _00000]. Minebea Intec EN-23...
Page 26
The Display will show the high limit value with all digit flashing [00510.0] (in this example, 510 pcs). 18. Press the (Yes) button to accept high limit value. The scale is ready for check counting application with new checklimit. Go on step EN-24 Minebea Intec...
Page 27
21. Place container on the scale (in this example, 109 pcs). Taring the container on scale. 22. Press the button with [NET] appear beside the weight value. 23. Place sample in the container. Minebea Intec EN-25...
Totalization manual is set to ON by default. 5.2.4.1 Procedure on Setting up the Totalization Application To enter into menu mode, press and hold the button until [M.E.N.U] is Menu displayed. Release the button. The 1 menu item [APPLIC] shown on display. EN-26 Minebea Intec...
Page 29
Menu 5.2.4.2 (Totalization) Displayed Values The Totalization Mode is active when icon is displayed. Put the first item on the scale. 2. Press the button to add the weight to accumulation data (under manual mode). Menu Minebea Intec EN-27...
Page 30
4. Put another sample on scale and follow same operation (Automatic or Manual mode). icon will keep flashing until the weight is removed. 5.2.4.3 Viewing and Clearing Statistical Data The pan must be empty to view the stored statistics. Empty the weighing pan. EN-28 Minebea Intec...
Page 31
Totalized value (TOTAL = 5.225g) Minimum value (Min = 0.47kg): Maximum value (Max = 1.485kg) To clear the totalizing memory: 3. Press and hold the button while the pan is unloaded and the totalizing data is displayed. Minebea Intec EN-29...
Page 32
Gross loads and net loads cannot be added to the same total. If the first load is a gross weight, following loads must also be gross weights. If the first load is a net weight, following loads must also be net weights. EN-30 Minebea Intec...
Mode Unit previous menu item. The 2 menu item [METRO] shown on display. When viewing the setting (in this example [APPLIC] - [WEIGH] - [STAB.RA] value 0.5d). Minebea Intec EN-31...
Enter this menu to select application to be used. Only activated units will be accessible with the (Mode) Button. Mode Default settings are identified by an "*" APPLIC — WEIGH Weighing mode — OFF disabled — ON enabled* — COUNT Count mode EN-32 Minebea Intec...
— END Leave menu level 6.2.3 Menu Selection [UNIT] Enter this menu to customize weighing unit to be used. Only activated units will be accessible with the (Unit) Button. Unit Default settings are identified by an "*" Minebea Intec EN-33...
Back lighting time (D.LIGHT = AUTO) — 3 SEC Backlight off after 3 minutes of no activity — 5 SEC Backlight off after 5 minutes of no activity* — 8 SEC Backlight off after 8 minutes of no activity EN-34 Minebea Intec...
— ON enabled — TARE Tare — OFF disabled* — ON enabled — HEADER Header info — OFF disabled* — ON enabled — FOOTER Footer info — OFF disabled* — ON enabled — MODE Mode info Minebea Intec EN-35...
— OFF Unlock* — ON Locked — S.PC.OUT PC Output Menu — OFF Unlock* — ON Locked — S.PC.COM PC Communication Menu — OFF Unlock* — ON Locked — S.CAL.AD Calibration / Adjustment Menu — OFF Unlock* EN-38 Minebea Intec...
Page 41
6 Menu Settings Weight indicator Puro® — ON Locked — RESET Restore factory setting of current menu — OFF Unlock* — ON Locked — END Leave menu level Minebea Intec EN-39...
Unit Mode menu item. 3. Change menu item until [CAL.ADJ] is displayed. 4. Press (Yes) button to enter into sub-menu item. Sub-menu item [CAL] (Calibration) is displayed. EN-40 Minebea Intec...
Page 43
8. For changing the calibration weight value, press the (No) button to edit the Unit value. The first digit is blinking [_015.000 kg]. 9. Press (Yes) button to accept and highlight the next digit. The 2nd digit is blinking [0_15.000 kg]. Minebea Intec EN-41...
[--C--] will be displayed while calibration weight is stored. In case of any mistake during the calibration process [CALE] (Calibration Error) is displayed. 14. Remove the weight after finish. The scale is ready for weighing. [LIN] Linearity Calibration Procedure Enter into Menu Mode: EN-42 Minebea Intec...
Page 45
5. Change menu item until [LIN] shows on display. 6. Press (Yes) button to start zero point calibration. [0 kg] shows on display. [0] is blinking. 7. Empty the weighing pan. 8. Press the (Yes) button to confirm. Minebea Intec EN-43...
Page 46
The display will show the linearization weight value at 100% of scale capacity with all digit blinking [00150.0] (in this example, 150 kg). 11. Put specified weight on pan. 12. Press (Yes) button to start linearity adjustment at 100% capacity. [--C--] is displayed while reading is stored. EN-44 Minebea Intec...
(Settings from 0 … 31 are available). Refer to table to determine the GEO factor that corresponds to your location. Enter into Menu Mode: Press and hold until [M.E.N.U] displayed. Menu Release the button. The 1 menu item [APPLIC] shown on display. Minebea Intec EN-45...
Page 48
(Yes) button to return to sub-menu selections. 11. Press (No) button to return to the first item in the current menu. Unit 12. Press the button to exit the setup menu and return to the weighing mode. Menu EN-46 Minebea Intec...
WARNING Improper repairs can pose considerable risks to the user. Repairs should only be performed by Minebea Intec authorized technical personnel using original spare parts. Cleaning 8.2.1 Cleaning instructions The device should be cleaned at regular intervals.
We reserve the right not to accept products that are contaminated with hazardous substances (ABC contamination) for repair. Should you have any further questions, please contact your local service representative. Minebea Intec Bovenden GmbH & Co. KG Repair center Leinetal 2 37120 Bovenden, Germany Phone: +49.551.30983.333...
10 Troubleshooting Weight indicator Puro® 10 Troubleshooting The Table lists common problems and possible causes and remedies. If the problem persists, contact Minebea Intec or your authorized dealer. Symptom Possible Cause Remedy Cannot turn on No power to scale Verify connections and voltage...
External, with freely selectable calibration weights Interface Built-in USB-C, Printer Port, RS232, LC Operating temperature (°C) -10...40 Storage temperature (°C) -20...50 Product dimension mm (w x d x h) 230 x 128 x 70 230 x 128 x 70 EN-52 Minebea Intec...
280 x 228 x 95 Net weight (kg) Shipping weight (kg) 11.3 Accessories (options) Option Order-No. Data Printer YP-DP1 Paper for Data Printer YP-P1 USB-C cable YP-CAC1 (not usable for PC communication) Printer cable YP-CAS1 USB Charger YP-PS1 Weighing hook YP-H1 Minebea Intec EN-53...
Page 57
11 Technical data Weight indicator Puro® all dimensions in mm / inch all dimensions in mm / inch all dimensions in mm / inch Minebea Intec EN-55...
Page 58
Weight indicator Puro® 11 Technical data all dimensions in mm / inch EN-56 Minebea Intec...
If Printx → Content → Info is ON OVER LIMIT 2.00 kg Information line If Printx → Content → Info is ON 12.2 Compliance Compliance to the following standards is indicated by the corresponding mark on the product. Minebea Intec EN-57...
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. EN-58 Minebea Intec...
Page 61
Published by Minebea Intec Bovenden GmbH & Co. KG | Leinetal 2 | 37120 Bovenden, Germany Phone: +49.551.309.83.0 | Email: info@minebea-intec.com www.minebea-intec.com...