Removing the NIM E-Series NCE from a Cisco ISR 4000 Series
Removing the NIM E-Series NCE from a Cisco ISR 4000 Series
Shutting Down the NIM E-Series NCE Installed in a Cisco ISR 4000 Series
Procedure
Step 1
Step 2
Restarting the NIM E-Series NCE Installed in a Cisco ISR 4000 Series
If the stop command is issued and the NIM E-Series NCE is not physically removed from the slot, you can
restart the NIM E-Series NCE with the start command. From a console terminal, issue the hw-module subslot
0/NIM-slot-number start command. The console displays the module's changing state.
Router# hw-module subslot 0/1 start
Inserting the NIM E-Series NCE in a Cisco ISR 4000 Series
A Cisco ISR 4000 series that is up and running can detect when an NIM E-Series NCE is inserted in the NIM
slot. After the router detects the NIM E-Series NCE, the router software enables power to the server.

Removing the COA

Note
The procedure to remove the COA is the same for M1, M2, and M3 servers.
In the event that you need to return the E-Series Server, make sure that you retain the original Certificate of
Authenticity (COA) label. The COA is the label from Microsoft with the code that enables their windows
software. After you return the server, Cisco Systems cannot retrieve the COA label from the returned server.
The COA label is attached to the inside half of a plastic pull out label tray. To remove the COA label, cut
away the half of the label that contains the COA label and save it. Return the unit with the other half of the
label tray, which contains the units CLEI code, serial number, and other important unit labels, to Cisco Systems
or your licensed reseller.
Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine Hardware Installation Guide
60
Command or Action
enable
Example:
enable
Router>
hw-module subslot 0/NIMslot-number stop
Example:
hw-module subslot 0/1 stop
Router#
Purpose
Enables privileged EXEC mode.
Enter your password if prompted.
Shuts down power to the specified NIM
E-Series NCE to prepare it for removal. The
NIM slot number can be 1, 2, or 3.
Note
Before removing the NIM E-Series
NCE, verify that power to the NIM
slot is shut down. The power LED
should be off.