Summary of Contents for Cisco UCS B200 M2

  • Page 1: Blade Server

    This product has been Spec Sheet discontinued Cisco UCS B200 M2 Blade Server ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 A.11 8, 2013 CTOBER CISCO...
  • Page 2: Table Of Contents

    Power Specifications ..........28 Cisco UCS B200 M2 Blade Server...
  • Page 3: Overview

    Xeon 5500 and 5600 Series processors with 12 DIMM slots, one mezzanine slot to hold an adapter card, and up to two solid-state disk (SSD) drives or hard disk drives (HDDs). Up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis. Figure 1...
  • Page 4: Detailed Views

    DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 is a detailed front view of the Cisco UCS B200 M2 Blade Server. Figure 2 Chassis Front View Asset tag (you can remove this tag and Network link status LED add your own)
  • Page 5: Base Server Standard Capabilities And Features

    CONFIGURING the SERVER on page Table 1 Capabilities and Features Capability/Feature Description Chassis The B200 M2 Blade Server mounts in a Cisco UCS 5100-series chassis Either 1 or 2 Intel® Xeon® 5500 or 5600 series processors Chipset Intel® 5500 chipset Memory...
  • Page 6: Configuring The Server

    CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES, page 14 ■...
  • Page 7: Step 1 Verify Base Sku

    Verify the product ID (PID) of the base server as shown in Table Table 2 PID of the Base B200 M2 Blade Server Product ID (PID) Description N20-B6625-1-UPG UCS B200 M2 Blade Server w/o CPU, memory, HDD, mezzanine The N20-B6625-1-UPG B200 M2 base server: Includes: ■ — KVM cable Does not include: ■...
  • Page 8: Step 2 Choose Cpu(S)

    DIMMs, the DIMMs will be clocked at the lower speed of 1066 MHz. Selecting higher-speed DIMMs: If you use 1333-MHz DIMMs with an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. Cisco UCS B200 M2 Blade Server...
  • Page 9 For optimal performance, select DIMMs with the highest clock speed for a given processor. If ■ you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS B200 M2 Blade Server...
  • Page 10: Step 3 Choose Memory

    DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per ■ channel, as shown in Figure Figure 3 B200 M2 Memory Organization Cisco UCS B200 M2 Blade Server...
  • Page 11 PID Description Voltage /DIMM DIMM Options UCS-MR-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/1R/x4/dual voltage 1.35/1.5 V UCS-MR-1X082RX-A 8GB DDR3-1333-MHz RDIMM/PC3-10600/2R/x4/dual voltage 1.35/1.5 V UCS-MR-1X162RY-A 16GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/dual voltage 1.35/1.5 V Memory Mirroring Option N01-MMIRROR Memory mirroring option Cisco UCS B200 M2 Blade Server...
  • Page 12 2 DIMMs in Channel E Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page ■ NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs. Cisco UCS B200 M2 Blade Server...
  • Page 13 4-GB and two 8-GB DIMMs. One 4-GB/8-GB DIMM pair would located on Channel A of CPU 1, and one 4-GB/8-GB DIMM pair would be located on Channel B of CPU 1. For more information regarding memory, see DIMM and CPU Layout on page Cisco UCS B200 M2 Blade Server...
  • Page 14: Step 4 Choose Hard Disk Drives Or Solid State Drives

    (1) Built-In LSI 1064E 4-port SAS 6.0G RAID Mezzanine card RAID controller Select up to two SAS or SATA drives listed in Table ■ Caveats You cannot mix HDD and SSD drives. You cannot mix SAS and SATA drive types. ■ Cisco UCS B200 M2 Blade Server...
  • Page 15: Step 5 Choose A Pcie Mezzanine Card

    PID Description Converged Network Adapters (CNA) N20-AC0002 UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb UCS-VIC-M82-8P Cisco UCS VIC 1280 dual 40 Gb capable Virtual Interface Card N20-AQ0102 Cisco UCS CNA M72KR-Q Qlogic Adapter N20-AE0102 Cisco UCS CNA M72KR-E Emulex Adapter N20-AI0102...
  • Page 16: Step 6 Choose Operating System And Value-Added Software

    Windows Server 2012 Standard (2 CPU/2 VMs) MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco Svc SUSE Linux Enterprise Server...
  • Page 17 VMware vCenter 5 Server Standard, 1 yr support required  VMW-VC5-STD-2A VMware vCenter 5 Server Standard, 2 yr support required  VMW-VC5-STD-3A VMware vCenter 5 Server Standard, 3 yr support required  VMW-VC5-STD-4A VMware vCenter 5 Server Standard, 4 yr support required  Cisco UCS B200 M2 Blade Server...
  • Page 18 Table 7 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required  UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers  Cisco UCS B200 M2 Blade Server...
  • Page 19: Step 7 Choose Operating System Media Kit

    Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media MSWS-12-DC2S-RM Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media Cisco UCS B200 M2 Blade Server...
  • Page 20: Step 8 Choose Service And Support Level

    UCSM upgrades. The Unified Computing Support Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain Cisco UCS B200 M2 Blade Server...
  • Page 21 Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a...
  • Page 22 With the Cisco Unified Computing Drive Retention (UCDR) service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
  • Page 23 24x7x4 Onsite CON-UCWD7-B200-M2SFF UCWD8 24x7x2 Onsite CON-UCWD8-B200-M2SFF For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS B200 M2 Blade Server...
  • Page 24: Order Optional Kvm Cable

    Product ID (PID) PID Description 37-1016-01 KVM Cable Figure 4 KVM Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB 2.0 connector (for a mouse and keyboard) Cisco UCS B200 M2 Blade Server...
  • Page 25: Supplemental Material

    6. The 6 DIMM slots at the upper right are controlled by the CPU on the right (CPU1) and the 6 DIMM slots at the lower left are controlled by the CPU on the left (CPU2). Cisco UCS B200 M2 Blade Server...
  • Page 26: Memory Population Recommendations

    A1, B1, C1 D1, E1, F1 A1, A2, B1, C1 D1, D2, E1, F1 A1, A2, B1, B2, C1 D1, D2, E1, E2, F1 A1, A2, B1, B2, C1, C2 D1, D2, E1, E2, F1, F2 Cisco UCS B200 M2 Blade Server...
  • Page 27 Your selected CPU(s) can have some effect on performance. ■ DIMMs can be run in a 1 DIMM per channel or a two DIMM per channel configuration. Each of ■ these arrangements can provide different behavior. Cisco UCS B200 M2 Blade Server...
  • Page 28: Technical Specifications

    1. The system weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs, memory DIMMs, and other optional items. Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/. Cisco UCS B200 M2 Blade Server...