  • Page 1 Spec Sheet Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model) ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 27, 2014 CISCO...
  • Page 2: Table Of Contents

    11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) ..... 42 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) ....43 STEP 13 ORDER USB 2.0 DRIVE (OPTIONAL) .
  • Page 3 Compliance Requirements ..........81 Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 4 Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 5: Overview

    OVERVIEW OVERVIEW The Cisco® UCS C220 M3 rack server is designed for performance and density over a wide range of business workloads from web serving to distributed database. The enterprise-class UCS C220 M3 server extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel®...
  • Page 6: Detailed Views

    USB, one VGA, and one serial connector) Temperature status LED Drives (up to four hot-swappable 3.5-inch drives) For more information about the KVM cable connection, see KVM CABLE, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 7: Chassis Rear View

    Rear Identification button/LED — — Serial port (RJ-45 connector) Notes . . . 1. Serial port pinout details are given in Serial Port Details, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 8: Base Server Standard Capabilities And Features

    The second SD card is blank and can be used to mirror the first SD card. It can ■ be used to protect the Hypervisor Partition with RAID1. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 9 1 GB cache and chassis-mounted (remote) supercap for data cache power backup, supporting RAID levels 0, 1, 5, 6, 10, 50, 60. Supports 8 external SAS ports (up to 240 external drives). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 10 Depending on your CIMC settings, the CIMC can be accessed through the 1-GbE processor dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 11: Configuring The Server

    STEP 16 SELECT SERVICE and SUPPORT LEVEL, page 49 ■ OPTIONAL STEP - ORDER RACK(s), page 54 ■ OPTIONAL STEP - ORDER PDU, page 55 ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 12: Step 1 Verify Server Sku

    Does not include power supply, CPU, memory, hard disk drives (HDDs), SD cards, or plug-in ■ PCIe cards. NOTE: Use the steps on the following pages to configure the server with the components that you want to include. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 13: Step 2 Select Cpu(S)

    8 GT/s 1866 UCS-CPU-E52650LB E5-2650LB v2 1.70 8 GT/s 1600 UCS-CPU-E52630LB E5-2630LB v2 2.40 7.2 GT/s 1600 UCS-CPU-E52609B E5-2609B v2 2.50 6.4 GT/s 1333 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 14 1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock. 2. 1866-MHz DIMMs cannot be used with Sandy Bridge CPUs Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 15 For configurations that use 130 W or 135 W CPUs, the minimum power supply required is ■ 650 W (UCSC-PSU-650W). See STEP 8 ORDER POWER SUPPLY, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 16: Step 3 Select Memory

    Memory is organized with four memory channels per CPU, with up to two DIMMs per channel, ■ as shown in Figure Figure 4 C220 M3 LFF Memory Organization Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 17 2. Dual voltage DIMM (operates at 1.5 V with BIOS is set for memory performance mode (default), or 1.35 V when BIOS is set for power-savings mode). 3. No longer shipping as of November, 2013 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 18 (3) 2-CPU configuration without memory mirroring: Select from 1 to 8 DIMMs per CPU. Refer to Memory Population Rules, page 59, for more ■ detailed information. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 19 NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 20 When single- and dual-rank DIMMs are populated for 2DPC, always populate the dual rank ■ DIMM in the blue DIMM slot, and the single-rank DIMM in the black DIMM slot (only the 4GB DIMMs are single-rank). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 21 For the DIMMs to run in power-savings mode (1.35 V, if the DIMM supports this), change the BIOS setting to power-savings mode. For more information regarding memory, see CPUs and DIMMs, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 22: Step 4 Select Raid Configuration

    Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and the number of drives ordered. Factory-configured RAID options are listed with each RAID card description. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 23 KVM are also not supported for use with the embedded MegaRAID controller Table 7 Available Mezzanine Card RAID Options Product ID (PID) PID Description Mezzanine RAID Controllers (not supported in 1-CPU systems) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 24 9271-8i) Factory-configured RAID options available: RAID 0, 1, 5, 6, and 10, (see ■ the RAID PIDs section in this table) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 25 Configuration section in this table). Note that factory RAID configuration is not available for these controllers, because the factory does not control the storage array attached to them. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 26 NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in Table 6 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 27 1 or allowed absent allowed allowed external slot 2 Installed 4 internal C220 M3 LFF Installed slot 1 or allowed allowed allowed slot 2 external Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 28 6. The mezzanine slot is not supported in 1-CPU systems Caveats Note that only a single Cisco VIC card (the half-height Cisco VIC 1225 or 1285 PCIe card) is ■ supported and it must be installed in the full-height PCIe slot (slot 1) on riser 1. So take this into account when populating RAID controller cards.
  • Page 29: Step 5 Select Hard Disk Drives (Hdds)

    Use the same capacity for each drive in the volume ■ Use either all SAS drives or all SATA drives ■ Use either all HDDs or all SSDs ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 30 Otherwise, select up to four SAS+SATA drives listed in Table 10. You can mix SAS and SATA ■ drives. Caveats You can mix SATA and SAS drives. ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 31: Step 6 Select Pcie Option Card(S)

    Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Half N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half N2XX-AQPCI03 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 32 — Neither PCIe slot 2 nor the mezzanine card slot are supported — Only a single VIC card (the Cisco VIC 1225 or 1285 PCIe card) is supported and it must be installed in slot 1 (the full-height slot). —...
  • Page 33: Step 7 Order Optional Network Card Accessories

    Only a single VIC card (the half-height Cisco VIC 1225 or 1285 PCIe card) is supported and it must be installed in slot 1 (the full height slot). — Only a single Cisco UCS 3.0 TB MLC Fusion ioDrive2 card is supported and it must be installed in slot 1 (the full height slot). —...
  • Page 34 SFP+ and twinax connections to the network cards. Caveats Check the table on the following page for compatibility between the PCIe network cards and SFPs or twinax cables. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 35 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA) N2XX-AQPCI03 Preinstalled - do not change SFP (QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 36 (Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics) Notes . . . 1. This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable. Figure 5 Network Card Connections Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 37: Step 8 Order Power Supply

    650 W power supply UCSC-PSU-930WDC 930 W -48V DC power supply NOTE: In a two power supply server, both power supplies must be identical. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 38: Step 9 Select Ac Power Cord(S)

    AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 39 EL 701 SFS-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel Cordset rating 10A, 250V/500V MAX (2500 mm) Connector: EL 701B Plug: (IEC60320/C13) EL 212 (SI-32) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 40 5-15 Plug, North America CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil 76.2 From Plug End 2,133.6 ± 25 CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 41: Step 10 Order Optional Reversible Cable Management Arm

    For more information about the cable management arm, see the Cisco UCS C220 M3 Installation and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/C220.pdf NOTE: All UCS C220 M3 servers ship with a tool-less rail kit. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 42: Step 11 Order A Trusted Platform Module (Optional)

    PID Description UCSX-TPM1-001 Trusted Platform Module NOTE: The module used in this server conforms to TPM v1.2, as defined by the Trusted Computing Group (TCG). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 43: Step 12 Order Cisco Flexible Flash Sd Card Module (Optional)

    32GB SD Card for UCS servers Caveats If you install a 32 GB SD card, you cannot install a 16 GB SD card. ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 44: Step 13 Order Usb 2.0 Drive (Optional)

    UCS-USBFLSH-S-4GB 4GB Flash USB Drive (shorter length) for all servers except C260 Figure 6 on page 56 for the location of the USB connector. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 45: Step 14 Select Operating System And Value-Added Software

    SLES for SAP Applications (1-2 CPU,Unl Vrt);1yr Support Reqd SLES-SAP-2S-UG-3A SLES for SAP Applications (1-2 CPU,Unl Vrt);3yr Support Reqd SLES-SAP-2S-UG-5A SLES for SAP Applications (1-2 CPU,Unl Vrt);5yr Support Reqd Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 46 Cisco Cloupia Resource Lic - One Phy Server node bare metal CUIC-PHY-SERV-U Cisco Cloupia Resource Lic - One physical Server node CUIC-TERM Acceptance of Cisco Cloupia License Terms Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 47 VMware vCenter 5 Server Standard, 4 yr support required  VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required  UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers  Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 48: Step 15 Select Operating System Media Kit

    Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media MSWS-12-DC2S-RM Windows Server 2012 Datacenter(2 CPU/Unlimited VM) Rec Media Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 49: Step 16 Select Service And Support Level

    SMARTNET 24X7X4 UCS C220 M3 Server - LFF CON-SNTE-C220M3LF SMARTNET 8X5X4 UCS C220 M3 Server - LFF CON-SNT-C220M3LF SMARTNET 8X5XNBD UCS C220 M3 Server - LFF Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 50 For additional information, see the following URL: www.cisco.com/go/partnerucssupport The two Partner Unified Computing Support Options include: Partner Support Service for UCS ■ Partner Support Service for UCS Hardware Only ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 51 Improve operational efficiency by allowing UCS experts to augment your internal staff ■ resources Enhance business agility by diagnosing potential issues before they affect your operations ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 52 With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
  • Page 53 For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 54: Optional Step - Order Rack(S)

    1. Use these same base PIDs to order spare racks (available only as next-day replacements). For more information about the R42610 rack, see RACKS, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 55: Optional Step - Order Pdu

    Table 30). Table 31 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 56: Supplemental Material

    SCU upgrade ROM header (RAID key). Cisco Flexible Flash SD socket SD1 on PCIe riser 2 DIMM slots on motherboard (16) Internal USB port Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 57: Cpus And Dimms

    H) are associated with CPU2. The bank 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding bank 2 (black) slots. Bank 1 slots (blue) are populated before bank 2 slots (black). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 58 SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks CPU1 CPU2 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 59: Memory Population Rules

    For optimal performance, all DIMMs in the same bank should be identical. 2. Only 1866-, 1600-, and 1333-MHz DIMMs are currently available for the C220 M3 server. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 60: Dimm Population Order

    A1, B1, C1, D1, E1, F1, G1, H1, A2, B2, C2, D2 E2, F2, G2, H2 Notes . . . 1. Not recommended (for performance reasons) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 61: Recommended Memory Configuration

    4x8 GB 4x16 GB 4x8 GB 1866 256 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1866 4x32 GB — 4x32 GB — 1866 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 62 4x8 GB 1600 256 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1600 4 x 32 GB — 4 x 32 GB — 1600 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 63 2. 32 GB LRDIMMs run in some cases at a maximum speed of 1333 MHz in 2DPC configurations, even though the specified DIMM speed is higher. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 64: Supported Dimm Populations

    128 GB 4 x 32 GB 128 GB 256 GB 8 x 32 GB 256 GB 8 x 32 GB 256 GB 512 GB Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 65: Low-Voltage Dimm Considerations

    CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage ■ DIMMs operating in Power Saving Mode only, and do not support Performance Mode. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 66: Raid Details

    BIOS and reconfiguring the option ROM (OPROM) settings. You may also select an appropriate optional RAID configuration listed in Table 8 on page 24 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 67: Raid Option Rom (Oprom) Settings

    An example OPROM BIOS screen is shown in Figure Figure 8 Example BIOS Screen for OPROM Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 68: Serial Port Details

    DTR (Data Terminal Ready) TxD (Transmit Data) GND (Signal Ground) GND (Signal Ground) RxD (Receive Data) DSR (Data Set Ready) CTS (Clear to Send) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 69: Upgrade And Servicing-Related Parts

    Notes . . . 1. This part is included/configured with your UCS server (in some cases, as determined by the configuration of your server). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 70: Drive Blanking Panels

    Adding an Additional CPU (with CPU heat sink) All Cisco UCS two CPU socket-capable servers can be upgraded from having one to having two CPUs configured. You will need to order and install a heat sink when adding any additional CPU to a server.
  • Page 71: Thermal Grease (With Syringe Applicator) For Cpu To Heatsink Seal

    CPU replacement process. Instructions for cleaning are found at the following link: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/replace.html#wp1233864 NOTE: When you purchase a spare CPU, the CPU cleaning kit is included. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 72: Racks

    (954 kg) Dynamic load capacity Not applicable Not applicable NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 73 SUPPLEMENTAL MATERIAL Figure 10 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 74: Pdus

    With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
  • Page 75: Kvm Cable

    Figure 12 KVM Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB connector (for a mouse and keyboard) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 76: Motherboard Usb And Sd Ports, And Raid Card Backup Location

    PCIe2 FAN3 FAN3 FAN3 PSU2 FAN4 FAN4 FAN4 FAN4 CPU2 FAN5 FAN5 FAN5 PSU1 SD1 socket USB connector SD2 socket SuperCap module mounting location Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 77: Technical Specifications

    3 A maximum @ 208 VAC Maximum AC inrush current 9 A peak @ 35° C, 208 VAC Maximum output power for the 450 W power supply Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 78 Main power: 12 VDC Standby power: 12 VDC Power supply efficiency CSCI Platinum NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 79 2.5 A minimum (within 40 - 72 VDC range) ■ For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 80: Environmental Specifications

    Sound Power level, Measure A-weighted per ISO7779 LWAd (Bels) Operation at 73°F (23°C) Sound Pressure level, Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 81: Compliance Requirements

    EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EMC - Immunity EN55024 CISPR24 EN300386 KN24 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
  • Page 82 TECHNICAL SPECIFICATIONS Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)