Cisco N20-B6625-1 Spec Sheet

Blade server

Advertisement

Cisco UCS B200 M2

Blade Server

C
S
ISCO
YSTEMS
170 W
T
D
.
EST
ASMAN
R
S
J
, CA, 95134
AN
OSE
.
.
WWW
CISCO
COM
P
H
UBLICATION
ISTORY
R
A.1
M
9, 2012
EV
ARCH
Spec Sheet

Advertisement

Table of Contents
loading

Summary of Contents for Cisco N20-B6625-1

  • Page 1: Blade Server

    Spec Sheet Cisco UCS B200 M2 Blade Server ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 9, 2012 ARCH CISCO...
  • Page 2: Table Of Contents

    Power Specifications ..........29 Cisco UCS B200 M2 Blade Server...
  • Page 3: Overview

    Xeon 5500 and 5600 Series processors with 12 DIMM slots, one mezzanine slot to hold an adapter card, and up to two solid-state disk (SSD) drives or hard disk drives (HDDs). Up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis. Figure 1...
  • Page 4: Detailed Views

    DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 is a detailed front view of the Cisco UCS B200 M2 Blade Server. Figure 2 Chassis Front View Asset tag (you can remove this tag and Network link status LED add your own)
  • Page 5: Base Server Standard Capabilities And Features

    CONFIGURING the SERVER on page Table 1 Capabilities and Features Capability/Feature Description Chassis The B200 M2 Blade Server mounts in a Cisco UCS 5100-series chassis Either 1 or 2 Intel® Xeon® 5500 or 5600 series processors Chipset Intel® 5500 chipset Memory...
  • Page 6: Configuring The Server

    CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES, page 14 ■...
  • Page 7: Step 1 Verify Base Sku

    Table Table 2 PID of the Base B200 M2 Blade Server Product ID (PID) Description N20-B6625-1-UPG UCS B200 M2 Blade Server w/o CPU, memory, HDD, mezzanine The N20-B6625-1-UPG B200 M2 base server: Includes: ■ — KVM cable Does not include: ■...
  • Page 8: Step 2 Choose Cpu(S)

    DIMMs, the DIMMs will be clocked at the lower speed of 1066 MHz. Selecting higher-speed DIMMs: If you use 1333-MHz DIMMs with an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. Cisco UCS B200 M2 Blade Server...
  • Page 9 For optimal performance, select DIMMs with the highest clock speed for a given processor. If ■ you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS B200 M2 Blade Server...
  • Page 10: Step 3 Choose Memory

    DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per ■ channel, as shown in Figure Figure 3 B200 M2 Memory Organization Cisco UCS B200 M2 Blade Server...
  • Page 11 DIMM Options UCS-MU-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/1R/x4/dual voltage 1.35/1.5 V UCS-MR-1X082RX-A 8GB DDR3-1333-MHz RDIMM/PC3-10600/2R/x4/dual voltage 1.35/1.5 V A02-M316GB1-L 16GB DDR3-1333MHz RDIMM/PC3-10600/2R/dual voltage 1.35/1.5 V Memory Mirroring Option N01-MMIRROR Memory mirroring option 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade Server...
  • Page 12 2 DIMMs in Channel E Select the memory mirroring option (N01-MMIRROR) as shown in Table 5 on page ■ NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs. Cisco UCS B200 M2 Blade Server...
  • Page 13 4-GB and two 8-GB DIMMs. One 4-GB/8-GB DIMM pair would located on Channel A of CPU 1, and one 4-GB/8-GB DIMM pair would be located on Channel B of CPU 1. For more information regarding memory, see DIMM and CPU Layout on page Cisco UCS B200 M2 Blade Server...
  • Page 14: Step 4 Choose Hard Disk Drives Or Solid State Drives

    (1) Built-In LSI 1064E 4-port SAS 6.0G RAID Mezzanine card RAID controller Select up to two SAS or SATA drives listed in Table ■ Caveats You cannot mix HDD and SSD drives. You cannot mix SAS and SATA drive types. ■ Cisco UCS B200 M2 Blade Server...
  • Page 15: Step 5 Choose A Pcie Mezzanine Card

    UCS M71KR-E Emulex Converged Network Adapter/PCIe/2port 10Gb N20-AC0002 UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb N20-AQ0102 Cisco UCS CNA M72KR-Q QLogic Converged Network Adapter N20-AE0102 Cisco UCS CNA M72KR-E Emulex Converged Network Adapter N20-AI0102 Cisco UCS CNA M61KR-I Intel Converged Network Adapter...
  • Page 16: Step 6 Choose Operating System

    RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd RHEL-SFS-2S-3A RHEL Option/Scalable File System/2 Socket/3 Yr Svcs Required RHEL-HA-2S-1A-RS RHEL Option/High-Availability/2 Socket/1Yr Redhat Svcs Incld RHEL-RS-2S-1A-RS RHEL Option/Resilient Storage/2 Socket/1 Yr Redhat Svcs Incl Cisco UCS B200 M2 Blade Server...
  • Page 17 VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMW-VC5-ST-1A VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMW-VC5-ST-2A VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade Server...
  • Page 18 VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMW-VC5-ST-4A VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R Cisco UCS B200 M2 Blade Server...
  • Page 19: Step 7 Choose Operating System Media Kit

    RHEL 6 Recovery Media Only (Multilingual) SLES-11 SLES 11 media only (multilingual) MSWS-08R2-STHV-RM Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media MSWS-08RS-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server...
  • Page 20: Step 8 Choose Optional Value-Added Software

    Table Table 10 Value Added Software Product ID (PID) PID Description N1K-CSK9-UCS-404 Cisco Nexus 1000V VSM Virtual Appliance Software BMC-012 BMC BPPM Per Server BMC-SE-4C BMC BladeLogic Standard Edition, 4 Cores, Support Required BMC-SE-6C BMC BladeLogic Standard Edition, 6 Cores, Support Required...
  • Page 21: Step 9 Choose Service And Support Level

    UCSM upgrades. The Unified Computing Support Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain Cisco UCS B200 M2 Blade Server...
  • Page 22 Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a...
  • Page 23 With the Cisco Unified Computing Drive Retention (UCDR) service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
  • Page 24 24x7x4 Onsite CON-UCWD7-B200-M2SFF UCWD8 24x7x2 Onsite CON-UCWD8-B200-M2SFF For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS B200 M2 Blade Server...
  • Page 25: Order Optional Kvm Cable

    Product ID (PID) PID Description 37-1016-01 KVM Cable Figure 4 KVM Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB 2.0 connector (for a mouse and keyboard) Cisco UCS B200 M2 Blade Server...
  • Page 26: Supplemental Material

    6. The 6 DIMM slots at the upper right are controlled by the CPU on the right (CPU1) and the 6 DIMM slots at the lower left are controlled by the CPU on the left (CPU2). Cisco UCS B200 M2 Blade Server...
  • Page 27: Memory Population Recommendations

    A1, B1, C1 D1, E1, F1 A1, A2, B1, C1 D1, D2, E1, F1 A1, A2, B1, B2, C1 D1, D2, E1, E2, F1 A1, A2, B1, B2, C1, C2 D1, D2, E1, E2, F1, F2 Cisco UCS B200 M2 Blade Server...
  • Page 28 Your selected CPU(s) can have some effect on performance. ■ DIMMs can be run in a 1 DIMM per channel or a two DIMM per channel configuration. Each of ■ these arrangements can provide different behavior. Cisco UCS B200 M2 Blade Server...
  • Page 29: Technical Specifications

    1. The system weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs, memory DIMMs, and other optional items. Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/. Cisco UCS B200 M2 Blade Server...
  • Page 30 TECHNICAL SPECIFICATIONS Cisco UCS B200 M2 Blade Server...

This manual is also suitable for:

Ucs b200 m2

Table of Contents