Cisco UCS C220 M4 Server Installation and Service Guide. This document describes the differences between the Cisco UCS C220 M4 Server and the network equipment building system- (NEBS-) compliant Cisco UCS C220 M4 NEBS Server. This document contains the following sections: •...
D R A F T: C i s c o C o n f i d e n t i a l NEBS Compliance The Cisco UCS C220 M4 NEBS Server has been certified for the following levels of NEBS compliance: The DC-power version of the server is certified for NEBS Level 3 compliance.
D R A F T: C i s c o C o n f i d e n t i a l Figure 1-1 Cisco UCS C220 M4 NEBS Server Rear Panel (AC Power Supply Version) #10-32 screw hole for grounding lug Installing a DC Power Supply A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Keyed DC input socket NEBS Server Component Support This NEBS server uses the small form-factor drives, eight-drive version of the Cisco UCS C220 M4 server. For the list of supported components in the NEBS version of the server and their ordering PIDs,...
Green, solid—12 V main power on; 12 V standby power on. • Amber, blinking—Warning threshold detected but 12 V main power on. • Amber, solid—Critical error detected; 12 V main power off (for example, • over-current, over-voltage, or over-temperature failure). Cisco UCS C220 M4 NEBS Server Service Note...
Page 6
D R A F T: C i s c o C o n f i d e n t i a l 770 W AC Power Supply Specifications Table 2 lists the specifications for each 770 W AC power supply (Cisco PID UCSC-PSU1-770W=). Table 2 770 W AC Power Supply Specifications...
Page 7
D R A F T: C i s c o C o n f i d e n t i a l 1050 W DC Power Supply Specifications Table 3 lists the specifications for each 1050 W DC power supply (Cisco PID UCSC-PSU2V2-1050DC=). Table 3...
DC Power Cord Table 1-2 describes the supported DC power cord. For the list of AC power cords supported with the server, see the Cisco UCS C220 M4 Server Installation and Service Guide. Table 1-2 Supported Power Cords for the Server Length...
OSP wiring. • The Cisco Unified Computing System (UCS) has AC power ports that are intended for deployments where an external Surge Protective Device (SPD) is utilized at the AC power service equipment (see the definition in National Electric Code).
CCVP, the Cisco logo, and Welcome to the Human Network are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco,...