Removing The Power Supply Unit; Installing The Power Supply Unit - Dell EMC PowerProtect X400H Replacement Procedure

Customer replaceable unit (cru) procedures
Table of Contents

Advertisement

Removing the power supply unit

Before you begin
1. Follow the
2. Identify the failed PSU by checking the Alerts and Events
Procedure
1. Disconnect the power cable from the power source and from the PSU you intend to remove,
2. Press and hold the orange release latch, and slide the PSU out of the X400 capacity cube by
After you finish
1.

Installing the power supply unit

Before you begin
1. Follow the
2. Ensure that both the PSUs are of the same type and have the same maximum output power.
Procedure
1. Slide the PSU into the X400 capacity cube until the PSU is fully seated and the release latch
CAUTION
The X400 capacity cube needs one power supply unit (PSU) for normal operation.
Since the X400 capacity cube is a power-redundant system, remove and replace only one PSU
at a time in a X400 capacity cube that is powered on.
safety
instructions.
PowerProtect Data Manager UI. Note down the node ID (for example, Capacity cube 06).
and then remove the cable from the strap on the PSU handle.
using the PSU handle.
Figure 22 Removing the power supply unit
Install the
PSU.
safety
instructions.
Note:
The maximum output power (shown in watts) is listed on the PSU label.
snaps into place.
If you feel any restriction while sliding in the PSU, visually inspect the opening for any
obstructions such as a cable that may have slipped.
PowerProtect X400 Appliance Customer Replaceable Unit (CRU) Procedures
X400 capacity cube CRU procedures
Appliance tab in the
>
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerprotect x400fPowerprotect x400

Table of Contents