FRU Removal and Replacement
2. On an AC power/cooling module, release the cable retention bail. and unplug the power
3. On a DC power/cooling module, pinch the spring releases on each side of the power cord
4. Remove the power/cooling module as follows:
Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide
26
cord.
Figure 13 Unplugging the power cord from an AC power supply/cooling module
plug and pull the plug out of the connector.
Figure 14 Unplugging the power cord from a DC power supply/cooling module
Spring
Release
CL5060
a. Press the orange handle button to release the module.
b. Pull the latch outward and remove the power/cooling module from its slot.
CAUTION
To protect a running system from overheating, the enclosure will power
down unless you replace the power cooling module within two minutes.