X400H Mid Hard Drive Replacement - Dell EMC PowerProtect X400H Replacement Procedure

Customer replaceable unit (cru) procedures
Table of Contents

Advertisement

3. In the PowerProtect Data Manager UI, on the Appliance page, verify that the capacity cube

X400H mid hard drive replacement

This section describes how to replace the three HDDs in the mid drive tray in physical slots 14, 15,
and 16 in an X400H capacity cube.
Removing the drive carrier from the mid drive tray
Before you begin
1. Follow the
2. Identify the faulted drive by checking the
3. Put the X400 capacity cube into maintenance mode in the PowerProtect Data Manager UI.
4.
5.
If the drive is online, the green activity/fault indicator flashes as the drive is turned off. When the
drive indicators are off, the drive is ready for removal.
Procedure
1. Lift the drive carrier handle upward.
2. Press the release tab on the drive tray and lift the drive carrier handle upward to disengage
3. Hold the drive carrier handle and lift the drive carrier out of the drive tray.
The Progress field shows the percentage of completion.
CAUTION
Do not force the disk to go Online. This can potentially corrupt the disk array
and result in data loss. Contact Dell EMC Support for assistance.
node status is online.
If the capacity cube node status is not online, go to the Alerts and Events page, select the
l
checkbox next to the alert related to the drive replacement procedure, and click
Acknowledge.
On the Appliance page, verify that the capacity cube node status is online.
l
safety
instructions.
the PowerProtect Data Manager UI. Note down the node ID (for example, Capacity cube 06)
and the drive number.
a. In the PowerProtect Data Manager UI, click the Appliance tab in the left navigation pane.
b. On the Appliance page, in the Capacity Cubes section, click the Details icon next to the
capacity cube you want to put into maintenance mode.
The Cube Details page appears.
c. On the Cube Details page, click Put Into Maintenance Mode.
A Capacity Cube-In Maintenance Mode job is created. You can monitor this job on
the Jobs page. The job takes approximately five minutes to complete.
Extend the X400 capacity cube from the
Remove the X400 capacity cube
the drive from the backplane.
PowerProtect X400 Appliance Customer Replaceable Unit (CRU) Procedures
alerts
in the Alerts and Events
rack.
cover.
X400 capacity cube CRU procedures
Appliance tab in
>
33