Table 5 Status LED indicators and descriptions (continued)
Icon
Description
Electrical
indicator
Memory
indicator
PCIe indicator The indicator turns
PowerProtect X400 Appliance Customer Replaceable Unit (CRU) Procedures
Condition
Corrective action
system experiences a
l
thermal error (for
example, the ambient
l
temperature is out of
range or there is a fan
l
failure).
l
The indicator turns
Check the System Event Log or system
solid amber if the
messages for a failed PSU. If it is due
system experiences
to a problem with the PSU, check the
an electrical error (for
LED on the PSU. Check for loose
example, voltage out
power cords. Re-seat the PSU or
of range, or a failed
replace if necessary.
power supply unit
(PSU) or voltage
regulator).
The indicator turns
Check the System Event Log or system
solid amber if a
messages for the location of the failed
memory error occurs.
memory. Re-seat the memory module
or replace if necessary.
Check the System Event Log or system
solid amber if a PCIe
messages for the location of the failed
card experiences an
PCIe and replace if necessary.
error.
X400 capacity cube CRU procedures
A cooling fan has been removed or
has failed.
Ambient temperature is too high.
External airflow is obstructed.
System cover, memory module
blank, or back filler bracket is
removed.