Table 5 Status LED indicators and descriptions (continued)
Icon
Description
Electrical
indicator
Memory
indicator
PCIe indicator The indicator turns
PowerProtect X400 Appliance Customer Replaceable Unit (CRU) Procedures
Condition
Corrective action
system experiences a
l
thermal error (for
example, the ambient
l
temperature is out of
range or there is a fan
l
failure).
l
The indicator turns
Check the System Event Log or system
solid amber if the
messages for a failed PSU. If it is due
system experiences
to a problem with the PSU, check the
an electrical error (for
LED on the PSU. Check for loose
example, voltage out
power cords. Re-seat the PSU or
of range, or a failed
replace if necessary.
power supply unit
(PSU) or voltage
regulator).
The indicator turns
Check the System Event Log or system
solid amber if a
messages for the location of the failed
memory error occurs.
memory. Re-seat the memory module
or replace if necessary.
Check the System Event Log or system
solid amber if a PCIe
messages for the location of the failed
card experiences an
PCIe and replace if necessary.
error.
X400 capacity cube CRU procedures
A cooling fan has been removed or
has failed.
Ambient temperature is too high.
External airflow is obstructed.
System cover, memory module
blank, or back filler bracket is
removed.
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerprotect x400fPowerprotect x400