No Charging Delivered; Normal Mode Or Charger Only Mode Not Working - TBB Energier Pro Series User Manual

Inverter charger combination
Hide thumbs Also See for Energier Pro Series:
Table of Contents

Advertisement

Phenomenon 5:No output,fault and overtemp lights illuminate.
Reason :Over temperature shutdown.
Solution :Check if there is good ventilation on installation site; check if fan was blocked.
Phenomenon 6:No output, long beep, fault light illuminate.
Reason :Fan failure/block.
Solution :Check if fan is blocked; check fan wire connection well.

9.3.3 No charging delivered

Reason 1:AC input wire loose connection.
Solution : Secure the connection.
Reason 2:Wrong connection of N and PE of AC input.
Solution : Correct the connection.
Reason 3:Check if using Generator as AC input.
Solution : Change working mode to GEN Mode through dip switch 8 at POWER PCB.
9.3.4 Normal mode and Power save mode keep changing over
Reason 1:Energier pro Inverter Charger Combination work in power save mode but the load was fluctuating .
Solution : Change work mode to normal mode.

9.3.5 Normal mode or Charger Only mode not working

Reason 1:The work mode setting on Energier pro Inverter Charger Combination and on RCF was different with each other.
Solution : Put main switch at Energier pro Inverter Charger Combination at OFF, using RCF to set the working mode.