It is strongly recommended to read this section carefully before you set the 
de‐sulphation charging and DO NOT leave battery unattended while performing 
de‐sulphation.
 
 
About Desulphation
Frequency: 
Maximum once a month, you may wish to equalize your flooded batteries by using 
the battery charger equalization mode. 
 
Important: 
Equalization can damage your batteries if it is not performed properly. Never 
equalize a battery more than twice a month. Always check battery fluid before and 
after equalization. Fill batteries only with distilled water. 
 
 
 
Always check the equalization switch is set back to OFF after each time's 
equalization. 
 
 
Battery manufactures' recommendations on equalization vary. Always follow the 
battery manufacturer's instructions so batteries are properly equalized. As a guide, a 
heavily used battery may require equalization once a month while a battery in light 
duty service, only needs equalizing once every 2 to 4 months. 
 
Battery type 
Only perform equalization to flooded lead‐acid batteries. Do not equalize Gel, AGM 
batteries. 
 

Performing an Equalization

During equalization, the battery generates potentially flammable gases. Follow all the 
battery safety precautions listed in this guide. Ventilate the area around the battery 
thoroughly and ensure that there are no sources of flame or sparks in the vicinity     
 
When battery temperature reach above 50C, please stop charging.     
 
 
 