4.1 Battery Capacity

Through the clock switch, you can configure the battery you are going to connected for a premium charging current. The charger
capacity in specification was the max charge current the model you selected could supply. Please refer to following fig of setting.
The charging current was set at following terms:
I=0.15C (15% of the battery capacity you choose)
Or
Max Charger Capacity of the model you choose.
In case you choose ≤50 AH, the charge current was 7.5 A.
In case you choose ≥900 AH, the charge current was the max charging current.
The max charging current of the model you are using can only deliver is its max charging current as specified in data no matter how big
battery you selected.
In case you want to charge your battery faster, you could set bank one gear larger to get higher charging current. However, please make
sure the current did not exceed 0.2C (20% of battery capacity).
For example, for model CF1650L with battery capacity of 12V/200AH.
1) If you choose battery capacity at 200 AH, you could get charging current of 15%x200 AH = 30 A
2) If you want to charge faster, you could choose 300AH, you could get charging current 15%x300AH = 45 A.
For example, for model CF1650L with battery capacity of 12 V / 400 AH.
since the max charging current of this model is 50 A, you will get 50 A. Not 0.15C, 60 A.
The default setting was position 0 (≤50 AH)
Position
0
1
2
3
4
5
6
7
8
9
Battery Capacity
≤50 AH
100 AH
200 AH
300 AH
400 AH
500 AH
600 AH
700 AH
800 AH
≥900 AH