Example#3
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
sleeping
sleeping
0H
15
th
M
Wakes up and
Wakes up and
collects data
collects data
REPORTS 3.6V
3.6V Does not
report
Notes :
1)
The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect data.
2)
The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the device reports according to MinTime interval. If the data
variation is not greater than the last data reported, the device reports according to MaxTime interval.
3)
We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up frequently and the battery will be drained soon.
4)
Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another cycle of MinTime/MaxTime calculation is started.

6. Installation

Thermocouples have positive and negative poles, with the + mark on the bare device as the direction, the second and third holes as a group, the 4th and
5th holes as a group, the 2nd and 4
line) of thermocouples. This product comes with a waterproof function. When using it, you can attach the back side to the iron surface, or use screws to
fix both ends to the wall.
Note: To install the battery, use a tool such as a screwdriver to open the battery cover.

7. Important Maintenance Instruction

Your device is a product of superior design and craftsmanship and should be used with care. The following suggestions will help you use the warranty
service effectively.
• Keep the equipment dry. Rain, moisture, and various liquids or moisture may contain minerals that can corrode electronic circuits. In case the
device is wet, please dry it completely.
• Do not use or store in dusty or dirty areas. This can damage its detachable parts and electronic components.
• Do not store in excessive heat. High temperatures can shorten the life of electronic devices, destroy batteries, and deform or melt some plastic parts.
• Do not store in a cold place. Otherwise, when the temperature rises to normal temperature, moisture will form inside, which will destroy the board.
• Do not throw, knock or shake the device. Rough handling of equipment can destroy internal circuit boards and delicate structures.
• Do not wash with strong chemicals, detergents or strong detergents.
• Do not apply with paint. Smudges can block debris in detachable parts and affect normal operation.
• Do not throw the battery into a fire to prevent the battery from exploding. Damaged batteries may also explode.
All of the above suggestions apply equally to your device, battery and accessories. If any device is not working properly.
Please take it to the nearest authorized service facility for repair.
Wakes up and collects data
3.5V |3.5-3.6|=0.1
REPORTS 3.5V
...
30
th
M
45
th
M
Wakes up and
collects data
3.5V Does not
report
th
holes connect to the positive (red line) of the thermocouple, the third and fifth holes connect to the negative (black
Users push the button,
REPORTS 3.5V.
Recalculate MaxTime.
1H
1H 10
th
M
1H 25
th
M
Wakes up and
Wakes up and
collects
data
collects
data
3.5V Does not
3.5V Does not
report
report
5
MaxTime
Wakes up and collects data
3.5V Does not report
1H 40
th
M
1H 55
th
M
Wakes up and
collects data
3.5V Does not
report
2H 10
th
M
Wakes up and
collects
data
REPORTS 3.5V