Type Tests And Environmental Conditions - Advantech ICR-3201 Series User Manual

Lan industrial router
Hide thumbs Also See for ICR-3201 Series:
Table of Contents

Advertisement

7.3 Type Tests and Environmental Conditions

Phenomena
Test
ESD
EN 61000-4-2
RF field AM
EN 61000-4-3
modulated
Fast transient
EN 61000-4-4
Surge
EN 61000-4-5
RF conducted
EN 61000-4-6
Radiated emission
EN 55032
Conducted
EN 55032
emission
Dry heat
EN 60068-2-2
MIL-STD-810G
SAE J1455
Cold
EN 60068-2-1
MIL-STD-810G
SAE J1455
Dump heat
EN 60068-2-78
MIL-STD-810G
SAE J1455
Vibration
EN 60068-2-64 ed. 2
MIL-STD-810G
SAE J1455
Shock
EN 60068-2-27 ed. 2
MIL-STD-810G
SAE J1455
Table 16: Type tests and environmental conditions
Description
Test levels
Enclosure contact
6 kV (crit. A)
Enclosure air
8 kV (crit. A)
Enclosure
10 V/m (crit. A)
(80 – 2700 MHz)
3 V/m (crit. A)
(2700 – 6000 MHz)
Signal ports
1 kV (crit. A)
Power ports
2 kV (crit. A)
Ethernet ports
1 kV (crit. A)
Ethernet ports
1 kV (crit. A), shielded cab.
Power ports
0,5 kV (crit. A)
All ports
10 V/m (crit. A)
(0,15 – 80 MHz)
Enclosure
Class B
DC power ports
Class B
Ethernet ports
Class B
+75 C *, 40 % rel. humidity
-40 C *
95 % rel. humidity (+40 C)
Vibration spectrum
Category 1 (3 axis, 8 hours
A.3 (rolling stock)
per axis)
half-sine, 50 g peak, 11 ms
24
ICR-3201

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icr-3201w

Table of Contents