Advantech ICR-2030 User Manual

Advantech ICR-2030 User Manual

Lte industrial router

Advertisement

Quick Links

LTE Industrial Router
ICR-2031
USER MANUAL
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de

Advertisement

Table of Contents
loading

Summary of Contents for Advantech ICR-2030

  • Page 1 LTE Industrial Router ICR-2031 USER MANUAL LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de...
  • Page 2 ICR-2031 c 2022 Advantech Czech s.r.o. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part of Advantech.
  • Page 3 Advantech Czech s.r.o., Sokolska 71, 562 04 Usti nad Orlici, Czech Republic Document No. MAN-0057-EN, revision from April 4, 2022. Released in the Czech Republic. LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de...
  • Page 4: Table Of Contents

    ICR-2031 Contents 1 Product Overview 1.1 Product Introduction ....... . . 1.2 Product Usage Examples .
  • Page 5 ICR-2031 Appendix D: Related Documents LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de...
  • Page 6 ICR-2031 List of Figures Access to the Internet from LAN ......Backed up Access to the Internet .
  • Page 7 ICR-2031 List of Tables Hardware Overview of the Router ......Order Codes Overview ....... . Contents of Package .
  • Page 8: Product Overview

    With open Linux platform and wide possibilities of programming customer SW applications in Python, C/C++. The Advantech existing app library Router Apps (User modules) with apps already developed to enhance specific router functionality including industrial protocol conversions and support of IoT platforms such as MS Azure, Cumulocity, ThingWorx, and others are supported on the router.
  • Page 9: Product Usage Examples

    ICR-2031 1.2 Product Usage Examples The router is primarily intended for these four basic situations: I. Access to the Internet from LAN Figure 1: Access to the Internet from LAN II. Backed up access to the Internet (from LAN) Figure 2: Backed up Access to the Internet LUCOM GmbH —...
  • Page 10: Using Vpn Tunnel

    ICR-2031 III. Secure networks interconnection or using VPN Figure 3: Using VPN Tunnel IV. Serial Gateway Figure 4: Serial Gateway LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de...
  • Page 11: Hardware Overview

    ICR-2031 1.3 Hardware Overview The router case preview is shown in Figure 5. A short description of hardware parts of the router is listed in Table 1, including the links to the chapters with a detailed description. Figure 5: Hardware Overview of the Router Item/Caption Type Description...
  • Page 12: Order Codes

    ICR-2031 Continued from previous page Item/Caption Type Description ETH0 RJ45 100 MB Ethernet connection for the first LAN, see Chap- ter 2.3. Connector for the first main antenna of the cellular module, see Chapter Connector for the first diversity antenna of the cellular module, see Chapter SIM slot micro-SIM...
  • Page 13: Package Contents

    ICR-2031 1.5 Package Contents The standard set of router includes items listed in the following table: Item# Description Figure Q’ty 1 pcs Router 1 set Wall mounting clip with screws 6-pin terminal block for power sup- 1 pcs ply, digital input and digital output (de- ployed on the router) 1 pcs Printed Quick Start Guide notes...
  • Page 14: Product Dimensions

    ICR-2031 1.6 Product Dimensions For the dimensions of the product see the figures below. Note that all sizes are measured in millimeters. Figure 5: Product Dimensions – Front View Figure 6: Product Dimensions (with wall mounting clip) – Top View LUCOM GmbH —...
  • Page 15: Mounting Recommendations

    ICR-2031 1.7 Mounting Recommendations The router can be placed: on a flat surface, on a wall using the wall mounting clip (see Chapter 1.8), on a DIN rail EN 60715 with the metal DIN rail clip (see Chapter 1.9) For most applications with a built-in router within a switchboard, it is possible to recognize two kinds of environments: A non-public, industry environment of low voltage with high interference, a public environment of low voltage and without high interference.
  • Page 16: Wall Mounting

    ICR-2031 1.8 Wall Mounting The wall mounting clip is supplied with the router as standard accessories. The router can be screwed to a wall (or another surface) using the wall mounting clip. There are two wholes on the clip with a diameter of 4 millimeters. For detailed information about the mounting dimensions see Figure in Chapter 1.6.
  • Page 17: Din Rail Mounting

    ICR-2031 1.9 DIN Rail Mounting The DIN rail clip is not supplied with the router as standard accessories, but it can be ordered by the order code BB-DIN-ICR32. The DIN rail clip is suitable for a DIN rail according to EN 60715 standard only. The default position of the clip is shown in Figure 8.
  • Page 18: Product Label

    ICR-2031 1.10 Product Label An example of the product label, with all the information printed on it, is in the figure below. Figure 10: Label Example LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de...
  • Page 19: Hardware Functionality

    ICR-2031 2. Hardware Functionality See Chapter for the product hardware overwiew. Table lists a short description of the hardware, including the links to the chapters with a detailed description. 2.1 SIM Card Slot Slot for one SIM card is located on the right panel of the router under a metal cover. It is necessary to insert an activated SIM card, to work properly.
  • Page 20: Cellular Antennas

    ICR-2031 2.2 Cellular Antennas Main (ANT) and diversity (DIV) antennas can be connected to the router using the SMA connectors located on the front panel. Do not run the router without connected cellular antenna connected to the main antenna connector as the energy from the transmission is effectively reflected by the open end and can damage the equipment.
  • Page 21: Power Supply

    ICR-2031 2.4 Power Supply The pins of power supply are physically connected to the 6-pin terminal block panel socket located on the left panel. The connection of power supply is shown in Figure and described in Table 3. Figure 7: Connection of Power Supply Signal mark Description PWR(+)
  • Page 22: I/O Port Interfaces

    ICR-2031 2.5 I/O Port Interfaces The maximum length of wires connected to the I/O ports is 3 meters to meet the EMC immunity conditions. The pins of I/O interface are physically connected to the 6-pin terminal block panel socket located on the left panel. The pinout of one binary input and one binary output is shown in Figure and described in Table 4.
  • Page 23: Led Status Indication

    ICR-2031 2.6 LED Status Indication There are LED indicators on the front panel of the router to provide router status informa- tion. Moreover, ETH connector, has two additional LEDs providing information about the port status. Caption Color State Description Green Starting of the router Green Blinking...
  • Page 24: Reset Functions

    ICR-2031 2.7 Reset Functions The RST button on the front panel can be used in three different situations: Reboot the router: Hold the RST button for less than 4 seconds, the router will be restarted. Factory reset – restore the default configuration: Hold the RST button for more than 4 seconds.
  • Page 25: Overview Of Router Reboot And Reset

    ICR-2031 Action Router behavior Trigger events – options Reboot Turns off and then Disconnect and reconnect the power. turns on the router Send text reboot via SMS to SIM card number put in your router (your phone number has to be authorized –...
  • Page 26: First Use

    ICR-2031 3. First Use 3.1 Powering up the Router The router will start up when a power supply is connected to it. By default, the router will automatically log on to the default APN of the inserted SIM card. The DHCP server will assign an addresses to the devices connected through the Ethernet port ETH0.
  • Page 27: Router's Web Interface

    ICR-2031 Figure 12: Router’s Web Interface A detailed description of the router settings in the web interface can be found in the configura- tion manual of the router. LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de...
  • Page 28: Technical Specifications

    ICR-2031 4. Technical Specifications 4.1 Basic Parameters Router parameters Temperature range Operating -40 C to +75 C Storage -40 C to +85 C Humidity Operating 5 to 95 % relative humidity non condensing Storage 5 to 95 % relative humidity non condensing Altitude Operating 2000 m / 70 kPa...
  • Page 29: Standards And Regulations

    ICR-2031 4.2 Standards and Regulations The router complies with the following standards and regulations: Standards and regulations Radio EN 301 511, EN 301 908-1, EN 301 908-2, EN 301 908-13 EN 301 489-1, EN 301 489-52, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-6-2, EN 55032 Safety...
  • Page 30: Type Tests And Environmental Conditions

    ICR-2031 4.3 Type Tests and Environmental Conditions Phenomena Test Description Test levels EN 61000-4-2 Enclosure 6 kV, L3 RF field AM EN 61000-4-3 Enclosure 20 V/m, 80 MHz-1 GHz, LX modulated 10 V/m, 1 GHz-6 GHz, L3 Fast transient EN 61000-4-4 DC port 1 kV, 5/50 Tr/Th ns, 100 kHz, L2 ETH - FTP...
  • Page 31: Parameters Of Cellular Module

    ICR-2031 4.4 Parameters of Cellular Module Technical parameters of cellular module Antenna Connector type: SMA Impedance: 50 LTE parameters LTE: LTE Cat.4, 3GPP Rel. 11 FDD frequencies: B28A (700 MHz), B20 (800 MHz), B8 (900 MHz), B7 (2600 MHz), B3 (1800 MHz), B1 (2100 MHz) TDD frequencies: B41 (2500 MHz), B40 (2300 MHz), B38 (2600 MHz) Bit rates: up to 150 Mbps (DL), 50 Mbps (UL)
  • Page 32: Parameters Of I/O Ports

    ICR-2031 4.5 Parameters of I/O Ports Electrical characteristics of the binary inputs are in Table 11. Status of the binary input is reported in the GUI on General Status page or can be retrieved in the Shell via io get bin0 command.
  • Page 33: Appendix A: Troubleshooting

    ICR-2031 Appendix A: Troubleshooting If you cannot connect to the router from your PC, your network card may be configured in such a way that it is not possible to connect to the router. Take one or more of the following steps in order to solve the problem: Make sure your PC’s network card is configured to obtain the IP address form the DHCP server (by default the DHCP server is running in the router).
  • Page 34 ICR-2031 I can’t access my Web server placed behind the router over NAT. The remote HTTP access to the router has to be disabled on "NAT Configuration" page in the router. Also enable "Send all remaining incoming packets to default server"...
  • Page 35 ICR-2031 Serial communication is not working. Verify that the router model supports serial communications. Also verify the serial communication settings. To do so, open the router’s configuration menu via the web browser, select the appropriate "Expansion Port" from "Configuration" part of the menu and verify the settings.
  • Page 36: Appendix B: Customer Support

    ICR-2031 Appendix B: Customer Support Customer Support for Europe Advantech Czech s.r.o. Sokolska 71 562 04, Usti nad Orlici, Czech Republic Phone: +353 91 792444 Fax: +353 91 792445 E-mail: iiotcustomerservice@advantech.eu Web: www.advantech.com Customer Support for NAM Advantech B+B SmartWorx...
  • Page 37: Appendix C: Regulatory & Safety Information

    ICR-2031 Appendix C: Regulatory & Safety Information Safety Notices Please, observe the following instructions: The router must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the utilization of the router in prescribed applications and environments.
  • Page 38 ICR-2031 Product Disposal Instructions The WEEE (Waste Electrical and Electronic Equipment: 2012/19/EU) directive was in- troduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimize the impact on the environment. This product contains high quality materials and components which can be recycled.
  • Page 39 Quick Start Guide for v2i Platform Configuration Manual for v2i Platform [EP] Product-related documents and applications can be obtained on Engineering Portal at address. https://icr.advantech.cz/download LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de...
  • Page 40 ICR-2031 We, Advantech Czech s.r.o., declare that the radio equipment narrated in this user’s manual complies with Radio Equipment Regulations 2017 (S.I. 2017 No. 1206). We, Advantech Czech s.r.o., declare that the radio equipment narrated in this user’s manual complies with Directive 2014/53/EU.

This manual is also suitable for:

Icr-2031

Table of Contents