Display A Temperature Fault By Means Of The Som Application - Siemens SIMATIC 627B Operating Instructions Manual

Box pc
Table of Contents

Advertisement

13.3

Display a temperature fault by means of the SOM application

Cause
Temperature errors do not occur during the normal approved use of the device. If the SOM
application indicates a temperature error and the "SOM" symbol in the status display
changing from green to red, check the following:
● Are the fan apertures covered?
● If the fan has failed (check speed display in the SOM)?
● Is the ambient temperature higher than the allowed value (see technical data)?
● Is the total output of the power supply within the specified limit?
● Are the heatsinks inside the PC covered with dust?
Remedy
The temperature fault is stored until the temperature drops back below the temperature
threshold and you acknowledge the error message in the SOM application.
● Click on the button with the "small broom" icon.
When the error message has been acknowledged, the "TEMP" LED goes out, the title bar
changes in the SOM application and the "SOM" symbol in the status bar changes from
red to green.
● Restart the PC, if you have not installed the SOM application.
SIMATIC Box PC 627B
Operating Instructions, 06/2008, A5E00927393-02
13.3 Display a temperature fault by means of the SOM application
Troubleshooting/FAQs