Siemens SIMATIC 627B Operating Instructions Manual page 174

Box pc
Table of Contents

Advertisement

Detailed descriptions
16.3 System resources
I/O address (hex)
0330
0340
0360
0370
0372
0376
0378
0380
03B0
03BC
03C0
03E0
03E8
03F0
03F6
03F7
03F8
Dynamic range; resources are managed by means of Plug and Play functionality
0400
0778
0780
0800
0810
0CFC
0D00
0F00
0F50
1000
1180
1800
8800
8C00
8870
8898
1880
FF00
172
033F
16
Not used
035F
32
Not used
0367
8
Not used
0371
2
SOM
0375
4
Not used
0376
1
Secondary EIDE channel
037F
8
LPT 1
03AF
48
Not used
03BB
12
Graphics
03BF
4
Reserved
03DF
16
Graphics
03E7
8
Not used
03EF
6
Reserved
03F5
6
Standard floppy disk controller
03F6
1
Primary EIDE channel
03F7
1
Standard floppy disk controller
03FF
8
COM1
0777
888
Not used
077F
8
ECP LPT 1
07FF
128
Not used
080F
16
ACPI communications range
0CFB
1260
PCI configuration index
0CFF
4
PCI configuration data
0EFF
512
Not used
0F4F
80
Super IO
0FFF
176
Not used
10FF
256
Used internally
11FF
128
Used internally
187F
128
Used internally
8BFF
1023
SATA RAID Controller
FEFF
29288
Not used for SATA RAID
8897
39
PATA RAID Controller
FEFF
30311
Not used for PATA RAID
886F
28655
Not used
FF0F
16
EIDE bus master register
Switchable in Setup,
then free
Switchable in Setup,
then free
Fixed
Fixed
Fixed
SIMATIC Box PC 627B
Operating Instructions, 06/2008, A5E00927393-02

Advertisement

Table of Contents
loading

Table of Contents