Alarm, error, and system messages
12.1 Boot error messages
On-screen error message
System RAM Failed at offset:
Shadow RAM Failed at offset:
Extended RAM Failed at offset:
Failing Bits:
Operating system not found
Previous boot incomplete
Default configuration used
System cache error Cache
disabled
Monitor type does not match
CMOS Run SETUP
System time-out
Real-time clock error
Keyboard controller error
124
Meaning / suggestions
Memory error.
Contact your technical support team.
Memory error.
Contact your technical support team.
Memory error.
Contact your technical support team.
Memory error.
Contact your technical support team.
Possible causes:
No operating system present
Wrong drive addressed (disk in drive A/B)
Incorrect active boot partition
Wrong boot drive settings in SETUP
Hard disk is not connected / defective
Abort of the previous BOOT procedure, for example, due to a
power failure. Adjust the settings in SETUP.
Error in the CPU's cache module.
Contact your technical support team.
The monitor does not match the SETUP entries.
Adapt the SETUP entries to the monitor.
Hardware error.
Contact your technical support team.
Clock chip error.
Contact your technical support team.
Keyboard error.
Contact your technical support team.