G-Customer Service Parameters; H-Adjusting Thermostat Set Point High - Traulsen UC Series Owner's Manual

Full-size undercounter refrigerators; full-size undercounter freezers; shorty cooktop refrigerators
Table of Contents

Advertisement

VII. g - CUSTOMER SERVICE PARAMETERS:
Listed below are the available parameters in the order they appear, using the down arrow key on the
controller. You can use either the up or down arrow keys to scroll through the options.
Thermostat Set Point High
Thermostat Set Point Low
Temperature Scale
Audible Alarm Style
Time (24-hour clock)
Date (month - day - year)
Daylight Savings
Start Manual Defrost
Defrost Lockout 1
VII. h - ADJUSTING THE THERMOSTAT SET POINT HIGH:
This parameter sets the high point of the desired cabinet temperature range. Typically, freezers will
range from -3° F to 0° F (-19° C to –18° C) and refrigerators will range from 36° F to 40° F (2° C to 4° C)
for this parameter setting. This parameter is preset at the factory and does not have to be adjusted
unless the customer chooses to do so. Note: Set Point Low and Set Point High cannot be set to the
same temperature. There will be at least 1-2 degree difference between the two settings.
Follow the instructions to enter the customer access code on page 9. When the control
display reads
Use the arrow keys
When the display shows the temperature you want press the set button
The display will then read
You can use the up or down arrow keys to scroll to the next parameter
or press the alarm cancel button to exit
VII. INTELA-TRAUL
Thermostat Set Point High. Press the set button
to adjust the temperature to your desired setting.
Thermostat Set Point High.
)
)
)
(continued)
®
Defrost Lockout 2
Defrost Lockout 3
Defrost Lockout 4
Room Temperature Offset
Ambient Air Sensor
Evaporator Coil Sensor
Discharge Line Sensor
Relative Humidity Sensor
.
-11-
.
SET
.
SET

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ul series

Table of Contents