This Traulsen unit is built to our highest quality standards. We build our refrigerators this way as a matter of pride. This philosophy has made Traulsen the
leader in commercial refrigeration since 1938. We thank you for your choice and confidence in Traulsen equipment and we know you will receive many years
of utility from this equipment.
All Traulsen units are placed on a permanent record file with the service department. In the event of any future questions you may have, please refer to the model
and serial number found on the name tag affixed to the unit. Should you need service, call us on our toll free number, 800-825-8220 between 7:30 am - 4:30
pm CST, Monday thru Friday. You may also log onto www.traulsen.com for further information. It is our pleasure to help and assist you in every possible way.
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION
INITIAL START DATE:
MODEL TYPE:
COMPANY/INDIVIDUAL NAME:
INSTALLER:
FORM NUMBER TR35746 (REV. 11-22-13)
Quality Refrigeration
Instructions for the installation, operation
and maintenance of Traulsen:
Door and Drawer Models
Compact Prep Tables UPT and UST Series: 27", 32", 48" and 60"
INSTALLER
SERIAL NO.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UHT Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Traulsen UHT Series

  • Page 1 All Traulsen units are placed on a permanent record file with the service department. In the event of any future questions you may have, please refer to the model and serial number found on the name tag affixed to the unit. Should you need service, call us on our toll free number, 800-825-8220 between 7:30 am - 4:30 pm CST, Monday thru Friday.
  • Page 2: Table Of Contents

    I. THE SERIAL TAG The serial tag is a permanently affixed label on which is recorded vital FORT WORTH, TX. electrical and refrigeration data about your Traulsen product, as well SERIAL MODEL as the model and serial number. This tag is located in the right interior VOLTS compartment on all standard models.
  • Page 3: Receipt Inspection

    NOTE: Traulsen does not recommend laying the unit down on its front, side or back. However, if you must please be certain NOTE: Traulsen units are not designed to be moved while on legs. If the unit to allow the unit to remain in an upright position afterwards for requires moving, a pallet jack or forklift should be used to prevent damage.
  • Page 4: D-Shelf Clips For Door Models

    III. g - CLEARANCE: It is important for the proper operation and longevity of your Traulsen unit that it have adequate provisions underneath for air supply to the compressor. There are no clearance requirements for the sides, rear or top.
  • Page 5: I-Installing The Stainless Steel Top

    III. INSTALLATION (continued) IV. OPERATION (continued) IV. b - TEMPERATURE CONTROL: III. i - INSTALLING THE STAINLESS STEEL TOP-UHT: The temperature is set at the factory but local conditions may necessitate slight All 27”, 32, 48, and 60” wide compact undercounter models can be adjustment.
  • Page 6: D-Refrigerating Product

    IV.OPERATION (continued) IV.OPERATION (continued) IV. f - DIVIDER BARS-DRAWERS: IV. c - DEFROST CONTROL: (continued) Drawer models are provided with metal divider bars standard. All 27” wide This control can be adjusted to set when the next defrost cycle will models are supplied with 2 bars, 32”...
  • Page 7: C-Cleaning The Condenser Coil

    V. CARE AND MAINTENANCE (continued) VI. MISC. OPERATIONS (continued) V. c - CLEANING THE CONDENSER COIL: Check the condenser coil periodically. The operating environment will affect Door the required frequency of cleaning. Air must be able to freely circulate through the condenser.
  • Page 8: D-Door & Drawer Gasket Replacement

    VI. MISC. OPERATIONS (continued) VI. d - DOOR & DRAWER GASKET(S) REPLACEMENT: Remove the old gasket by pulling it out from the gasket retainer. Next, install the four corners of the new gasket by pushing straight in on the gasket until it is hooked behind the gasket retainer.
  • Page 9: Service Assistance

    If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service agent. You may obtain the name of a service agent from the Service Directory page of our web site: www.traulsen.com. Please note, you will be required to register for a login name and pass code to access our directory.
  • Page 10: Warranties

    “Defective Part Return” – All claimed defective r e p l a c e m e n t part(s) must be returned to TRAULSEN for i n s p e c t i o n within 30 days from the date of the repair.
  • Page 11: Service Parts List

    X. SERVICE PARTS LIST Note: Part numbers listed are for standard products as currently manufactured. For products manufactured as other than standard, please contact the factory. ITEM DESCRIPTION PART NUMBER CASTERS 6” CASTER - 60” MODELS CASTER 5SET6 6” CASTER - 27”, 32” & 48” MODELS CASTER 5SET4 4”...
  • Page 12 X. SERVICE PARTS LIST (continued) Note: Part numbers listed are for standard products as currently manufactured. For products manufactured as other than standard, please contact the factory. ITEM DESCRIPTION PART NUMBER DRAWER 27 COMPACT DRAWER ASSEMBLY 550-10234-00 DRAWER TOP 550-10214-00 DRAWER BOTTOM 550-10233-00 DRAWER FACE ASSEMBLY TOP...
  • Page 13 NOTES:...
  • Page 14 HOURS OF OPERATION: Monday thru Friday 7:30 am - 4:30 pm CST raulsen 4401 Blue Moud Road Fort Worth, TX 76106 Phone (800) 825-8220 Fax (817) 740-6757 Website: www.traulsen.com Quality Refrigeration © 2013 Traulsen - All Rights Reserved...