F-Service Parameters; G-Adjusting Thermostat Set Point High - Traulsen TU048QC Owner's Manual

Table of Contents

Advertisement

VII. f-SERVICE PARAMETERS:
Listed below are the available parameters in the order they appear, using the down arrow key on the controller. You can
use either the up or down arrow keys to scroll through the options.
Thermostat Set Point High
Thermostat Set Point Low
Temperature Scale
Time (24-hour clock)
Date (month-day-year)
Daylight Savings
Start Manual Defrost
Defrost Lockout 1
Defrost Lockout 2
VII. g-ADJUSTING THERMOSTAT SET POINT HIGH:
This parameter sets the high point of the desired cabinet temperature range. Typically, Quick Chillers will range from 31°F
to 35°F. This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so.
Note: Set Point Low and Set Point High cannot be set to the same temperature. There must be at least 1-2 degree differ-
ence between the two settings.
Follow the instructions to enter the customer access code on page 8. When the control
display reads
Use the arrow keys
When the display shows the temperature you want press the set button
The display will then read
You can use the up or down arrow keys to scroll to the next parameter
or press the alarm cancel button to exit
VII. MICROPROCESSOR CONTROL (cont'd)
Thermostat Set Point High. Press the set button
to adjust the temperature to your desired setting.
Thermostat Set Point High.
)
)
)
.
Defrost Lockout 3
Defrost Lockout 4
Dew Point Compensation Factor
Room Temperature Offset
Audible Alarm Style
Cabinet Air Sensor Temp
Evaporator Coil Sensor Temp
Discharge Line Sen
SET
.
SET
.