Traulsen UC Series Owner's Manual
Traulsen UC Series Owner's Manual

Traulsen UC Series Owner's Manual

Full-size undercounter refrigerators; full-size undercounter freezers; shorty cooktop refrigerators

Advertisement

Quick Links

Traulsen & Co., Inc.
OWNER'S MANUAL
Instructions for the installation, operation
and maintenance of all Traulsen:
UC Series Full-Size Undercounter Refrigerators
UC Series Full-Size Undercounter Freezers
UL Series Shorty Cooktop Refrigerators
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers and heated
cabinets this way as a matter of pride. This philosophy has made Traulsen the leader in commercial refrig-
eration since 1938. We thank you for your choice and confidence in Traulsen equipment and we know you
will receive many years of utility from this equipment.
All Traulsen units are placed on a permanent record file with the service department. In the event of any
future questions you may have, please refer to the model and serial number found on the name tag affixed
to the unit. Should you need service, however, call us on our toll free number, 800-825-8220 between 7:30
am and 4:30 pm CST, Monday thru Friday. It is our pleasure to help and assist you in every possible way.
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION
INITIAL START DATE:
MODEL TYPE:
COMPANY/INDIVIDUAL NAME:
INSTALLER:
FORM NUMBER TR35745 REV. 5/03
Quality Refrigeration
INSTALLER
SERIAL NO.
P/N 375-60183-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UC Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Traulsen UC Series

  • Page 1 All Traulsen units are placed on a permanent record file with the service department. In the event of any future questions you may have, please refer to the model and serial number found on the name tag affixed to the unit.
  • Page 2: Table Of Contents

    The serial tag is a permanently affixed sticker on which is recorded vital electrical and refrigeration data about your Traulsen product, as well as the model and serial number. This tag is located in the right interior compartment on all full size undercounter and equipment stand models.
  • Page 3: Receipt Inspection

    Under no condition may a damaged unit be re- turned to Traulsen & Co. without first obtaining writ- ten permission (return authorization). III. INSTALLATION III.
  • Page 4: D-Installing Casters

    III. d - INSTALLING LEGS OR CASTERS (cont’d): Please note that Traulsen units are not designed to be moved while on legs. If the unit requires moving, a pallet jack or forklift should be used to prevent dam- age. For installing casters, the casters are “plate”...
  • Page 5: C-Condensate Removal

    V. CARE & MAINTENANCE V. a - CLEANING THE CONDENSER: The most important thing you can do to insure a long, reliable service life for your Traulsen is to regularly clean the condenser coil. The condensing unit requires regularly scheduled cleaning to keep the finned condenser clean of lint and dust accummulation.
  • Page 6: B-Re-Hinging The Door(S)

    VI. a - ADJUSTING THE SHELVES (cont’d): rotating clockwise. Make sure the pin is securely tight- ened down. Do not over tighten. Slide the shelf into its new position, and replace the white plastic covers into the holes vacated by the shelf pins. VI.
  • Page 7 VI. MISC. OPERATIONS (cont’d) Fig. 7a Remove Louver Assembly Fig. 7b Fig. 9 Removing Power Pack...
  • Page 8: Intela-Traul

    Your new Traulsen Undercounter Refrigerator or Freezer is equipped with a state-of-the-art electronic microproces- sor INTELA-TRAUL control, which precisely regulates operation and provides alarms when problems occur. It is ® supplied from the factory completely ready for use but without the audible alarms activated. See pages 8 thru 17 for more information.
  • Page 9: B-Alarm Explanations

    VII. INTELA-TRAUL VII. b - ALARM EXPLANATIONS: *NOTE: Explanation of alarms assume the audible alarm style is set at a 3-second burst or a continuous audible alarm. References to the audible alarm do not apply if the audible alarm style is set to OFF (Refer to page 17 for setting the audible alarm style). High Cabinet Air Temperature: The audible alarm* will sound and the display will read HI CAb when the temperature inside the cabinet rises above a pre-programmed limit.
  • Page 10: C-Control Panel

    VII. c - CONTROL PANEL: ° LED FOR 3-DIGIT (RED) LED DISPLAY VII. d - PARTS ASSEMBLY: (UC/UL Cabinets) COIL SENSOR* 337-60071-00 (refrigerator & freezer only) CABINET SENSOR* 337-60069-00 INTELA-TRAUL** HORIZONTAL CONTROLLER 337-60062-00 HOLDER CLIP DEFROST COMPRESSOR RELAY POWER LINE IN 2 VII.
  • Page 11: E-Notes To The User

    VII. e - NOTES TO THE USER: You only have 20-30 seconds between button pushes. If you take longer than 30 seconds, the controller will revert back to displaying the cabinet temperature. If you enter the wrong security code, the controller will revert back to displaying the cabinet temperature.
  • Page 12: G-Customer Service Parameters

    VII. g - CUSTOMER SERVICE PARAMETERS: Listed below are the available parameters in the order they appear, using the down arrow key on the controller. You can use either the up or down arrow keys to scroll through the options. Thermostat Set Point High Thermostat Set Point Low Temperature Scale...
  • Page 13: I-Adjusting Thermostat Set Point Low

    VII. i - ADJUSTING THE THERMOSTAT SET POINT LOW: This parameter sets the low point of the desired cabinet temperature range. Typically, freezers will range from –6° F to -4° F (-21° C to –20° C) and refrigerators will range from 32° F to 34° F ( 0° C to 1° C) for this parameter setting.
  • Page 14: K-Setting The 24-Hour Clock

    VII. k - SETTING THE 24-HOUR CLOCK: The internal timeclock must be set in order for the data storage memory to correctly log events and to allow any defrost lockout to occur at the correct time of day. If the clock is not set, the control assumes the time is 12 am at the time power is supplied to the unit.
  • Page 15: L-Setting The Date

    VII. l - SETTING THE DATE: The date must be set in order for the data storage memory to correctly log events. Follow the instruc- tions to enter the customer access code on page 9. When the control displays Set Point High, press the down arrow key the set button .
  • Page 16: N-Starting A Manual Defrost

    INTELA-TRAUL ° ° NOTE: Traulsen refrigerator units also have an off-cycle defrost once an hour, at which time the control will read . This defrost is temperature terminated and can last from 3 - 10 minutes (dEF will be displayed for 22-27 minutes time).
  • Page 17: O-Setting Defrost Lockouts

    VII. o - SETTING THE DEFROST LOCKOUTS: The defrost lockout parameters allow the customer to prevent the unit from going into a defrost cycle for two hours during a set timeframe. Customers can set up to four defrost lockout parameters. They are all programmed the same way.
  • Page 18: P - Adjusting The Room Temperature Offset

    VII. p - ADJUSTING THE ROOM TEMPERATURE OFFSET: The room temperature offset parameter allows a service technician or end user the ability to have the display show a temperature that is within three degrees of the actual temperature being read by the cabinet air sensor.
  • Page 19: R-Viewing Sensor Temperatures

    VII. INTELA-TRAUL (continued) ® VII. r - VIEWING SENSOR TEMPERATURES: These parameters allow a service technician or customer to view the temperature of all sensors within the unit. The temperatures cannot be adjusted. Follow the instructions to enter the customer access code on page 9. When the control displays Thermostat Set Point High , press the DOWN arrow key unit the display reads...
  • Page 20: Trouble Shooting Guide

    VIII. TROUBLE SHOOTING GUIDE FIND YOUR PROBLEM HERE 1. Condensing unit fails to start. 2. Condensing unit operates for prolonged periods or continuously. 3. Food compartment is too warm. 4. Food compartment is too cold. 5. Condensation on the exterior surface. 6.
  • Page 21: Warranty Information

    TRAULSEN & CO., INC. warrants to the original purchaser the Refrigeration Equipment manufactured and sold by it to be free from defects in material and workmanship under normal use and service for a period of one (1) year from date of shipment. Under this warranty, TRAULSEN & CO., INC. will reimburse the purchaser for the replacement of any part of said equipment (excluding dryers &...
  • Page 22: Other

    X. c - WARRANTY REGISTRATION: For your convenience, the warranties on your new Traulsen unit may be registered with us by one of two methods. Completing the enclosed warranty card (shipped with the unit), or by filling out the on-line warranty registration form located on the Technical Service page of our website (www.traulsen.com).
  • Page 23: Index

    Alarms Audible Alarm Styles Cleaning Casters Condensate Evaporator Cord & Plug Customer Access Code Customer Service Parameters Daylight Savings Time Defrost Lockouts 6, 15 Data Storage Gaskets Hinge 4, 5 Internal Time Clock INTELA-TRAUL 3, 4, 5, 6-17 ® Legs Louver Assembly 4, 5 Manual Defrost Cycle...
  • Page 24: Hours Of Operation

    HOURS OF OPERATION: Monday thru Friday 7:30 am - 4:30 pm CST Quality Refrigeration Traulsen & Co., Inc. 4401 Blue Mound Road Fort Worth, TX 76106 Phone: (800) 825-8220 Fax-Svce: (817) 740-6757 Website: www.traulsen.com...

This manual is also suitable for:

Ul series

Table of Contents