FIND YOUR PROBLEM HERE
1. Condensing unit fails to start.
2. Condensing unit operates for
prolonged periods or continuously.
3. Food compartment is too warm.
4. Food compartment is too cold.
5. Condensation on the exterior surface.
6. Compressor hums but does not start.
VIII. TROUBLE SHOOTING GUIDE
a.
b.
a.
b.
c.
d.
a.
b.
c.
a.
b.
a.
b.
a.
-19-
REMEDY
Check if cord & plug has been disconnected.
Check INTELA-TRAUL
temperature setting.
®
Are doors closing properly?
Dirty condenser or filter. Clean properly.
Evaporator coil iced. Needs to defrost. See
instructions for setting a manual defrost cycle
on page 15.
Shortage of refrigerant, call service.
Check door(s) and gasket(s) for proper seal
Perhaps a large quantity of warm food has
recently been added or the door was kept
open for a long period of time, in both
cases, allow adequate time for the cabinet
to recover its normal operating temperature.
INTELA-TRAUL
setting too high, readjust
®
per instructions on page 11.
Perhaps a large quantity of very cold or frozen
food has recently been added. Allow adequate
time for the cabinet to recover its normal operating
temperature.
Adjust the INTELA-TRAUL
setting, see page 12.
Check door alignment and gaskets for proper seal.
Condensation on the exterior surface of the
unit is perfectly normal during periods of
high humidity.
Call for service.