1. RECEIPT & SUPPORT INSTALLATION
You should carefully inspect your Traulsen unit for damage during delivery. If damage is detected, you should save
all the crating materials and make note on the carrier's Bill Of Lading describing this. A freight claim should be filed
within 5 days.
Confirm that the correct power supply is available to the cabinet per the manufactures requirements as listed on the
cabinet data tag before cabinet installation. The area in which your cabinet is to be installed should be chosen carefully
to insure the best performance. The installation surface should be level and provide good area circulation.
Some models may use R-290 (Propane) as a refrigerant. If flammable refrigerant is present, follow instructions as
labeled on the unit. Proper care must be taken to avoid any damage to refrigeration system including refrigerant
tubing, condenser and evaporator coils during handling, moving, installation and cleaning as it may cause risk of fire
or explosion. If damaged, unit must be moved to well ventilated area away from any sources of ignition.
Further service and repair must be performed by qualified refrigeration technicians familiar with applicable safety
standards for flammable refrigerants. Technicians must use appropriate personal protective equipment and follow
applicable safety pre cautions to avoid risk of fire or explosion.
Most units are supplied with a cord and plug, which can simply be plugged into a dedicated appropriately sized outlet.
For those requiring hard-wiring directly to the power supply, this should be done by a qualified electrician only.
After uncrating the unit, select a level location for final placement. Install the legs or casters as shown below.
Compacts Supports ("Stem" type legs & casters)
Instructions for the installation, use and care
of:
UHT / ULT Series
Compact Undercounters
&
UPT / UST Series
Compact Prep Tables
TR36285 P/N 375-60375-00 (Rev.10/06/20)
-1-

Advertisement

Table of Contents
loading

Summary of Contents for Traulsen UHT Series

  • Page 1 1. RECEIPT & SUPPORT INSTALLATION You should carefully inspect your Traulsen unit for damage during delivery. If damage is detected, you should save all the crating materials and make note on the carrier’s Bill Of Lading describing this. A freight claim should be filed within 5 days.
  • Page 2: Control Basics

    2. CONTROL BASICS Your new Traulsen unit is equipped with a digital control, which precisely regulates operation. It is supplied from the factory completely ready for use. 2. a - INFORMATION MENU The information available in this menu is: * displayed only if enabled (see Configuration Parameters) ** displayed only if ACC > 0 Access to menu and information displayed: •...
  • Page 3 2. CONTROL BASICS (continued) 2. c - INITIATING A DEFROST Automatic defrost: Defrost starts automatically as soon as the time set with parameter DFT has elapsed. • Timed defrost: With DFM = TIM defrosts take place at regular intervals when the timer reaches the value of DFT. For example, with DFM = TIM and DFT = 36, a defrost will take place every 6 hours.
  • Page 4 2. CONTROL BASICS (continued) 2. e - OPERATION DISPLAY INDICATORS During normal operation, the display shows either the temperature measured or one of the following indications: 2. f - TECHNICAL DATA Power supply TRL-002..W 100-240Vac ±10%, 50/60Hz, 3W Relay output max loads (240Vac) TRL-002..S/T..-.
  • Page 5 2. CONTROL BASICS (continued) 2. g - COMPONENTS AND WIRING DIAGRAM Indications: Thermostat output Fan output Defrost output Activation of 2 patameter set Alarm Manual activation / Increase button Exit / Stand-by button Control Wiring Diagram:...
  • Page 6: General Care

    3. GENERAL CARE Disconnect electrical power supply before cleaning any parts of the unit. All Traulsen equipment should be cleaned only with warm water, mild soap and a soft cloth. Apply with a dampened cloth and wipe in the direction of the metal grain.
  • Page 7: Cleaning The Condenser

    6. CLEANING THE CONDENSER Disconnect electrical power supply before cleaning any parts of the unit. This is the single most important thing you can do to promote long, efficient equipment life. To clean the condenser, remove rear bottom perforated access panel. Vacuum or brush any dirt, lint or dust from the finned condenser coil, around the compressor and other cooling system parts as indicated.
  • Page 8: Troubleshooting

    Factory recommends to use exact make and models to assure the consistent performance and to minimize the risk of possible ignition due to incorrect parts. In case of uncertainty or parts unavailability, contact Traulsen technical assistance at 800-825-8220.
  • Page 9: Service And Warranty Information

    8. SERVICE & WARRANTY INFORMATION 8. a - SERVICE SUPPORT To speak to service support for Traulsen units please contact our Fort Worth, TX facility by phone at 800-825-8220 or by fax to 817-740-6748 (parts) or 817-740-6757 (service). Note: When calling for service support, please make sure you have model and serial number of unit available.
  • Page 10: Hours Of Operation

    HOURS OF OPERATION: Monday thru Friday 7:30 AM - 4:30 PM CST Traulsen 4401 Blue Mound Road Fort Worth, TX 76106 Phone (800) 825-8220 Service Fax (817) 740 6757 Quality Refrigeration www.traulsen.com TR36285 P/N 375-60375-00 (Rev. 10/06/20)