VII. p - ADJUSTING THE ROOM TEMPERATURE OFFSET:
The room temperature offset parameter allows a service technician or end user the ability to have the
display show a temperature that is within three degrees of the actual temperature being read by the
cabinet air sensor. This allows for continuity of reading between different temperature reading devices.
(i.e.: thermistor Vs thermocouple Vs handheld thermometer) This parameter is preset at the factory to
"0" or no offset.
Follow the instructions to enter the customer access code on page 9. When the control displays
Thermostat Set High, press the down arrow key
Room Temperature Offset. Press the set button
offset to your desired setting. When the display shows the offset you want press the set button
The display will then read
keys
to scroll to the next parameter or press the alarm cancel button to exit
VII. q - SETTING THE AUDIBLE ALARM STYLE:
This parameter will allow the customer to turn on/off the audible alarm feature on the INTELA-
TRAUL
control. The audible alarm is preset from the factory to OFF. The customer can choose
®
between an audible alarm that sounds for 3 seconds then automatically turns off, or a continuous
audible alarm that must be manually acknowledged. Regardless of this feature's setting, visual alarm
text will display when conditions warrant.
To adjust this setting, follow the instructions to enter the customer access code on page 9. When the
control displays
reads
Audible Alarm Style. Press the set button
Use the arrow keys
for Continuous Audible Alarm. When the display shows your choice of style, press the set
SET
button
. The display will then read
to scroll to the next parameter or press the Alarm Cancel Button
VII. INTELA-TRAUL
Thermostat Set Point High. You can use the up or down arrow
Thermostat Set Point High, press the up arrow key
to scroll between
(continued)
®
until the control display reads
.
Use the arrow keys
SET
SET
. The display will read
for the 3-Second Audible Alarm Burst or
thermostat Set Point High. Use the arrow keys
-17-
to adjust the
)
)
.
)
until the display
OFF.
)
)