Your new Traulsen Undercounter Refrigerator or Freezer is equipped with a state-of-the-art electronic microproces-
sor INTELA-TRAUL
control, which precisely regulates operation and provides alarms when problems occur. It is
®
supplied from the factory completely ready for use but without the audible alarms activated. See pages 8 thru 17 for
more information.
VII. a - INTELA-TRAUL
Internal Time Clock
• Eliminates defrost time clock.
• Will display only at "Start Up".
• Must be reset after a power failure.
• See "Setting The 24-Hour Clock" on Page 12 (Also required at "Start Up").
• Will automatically update for Daylight Savings Time. See "Setting Daylight Savings Time" on page 13.
Water Resistant Housing
The INTELA-TRAUL
®
housing.
Parameter/Service Levels
• See "Customer / Service Parameters" on Page 9.
Defrost Lockouts - See "Setting Defrost Lockouts" on page 15.
• Customers can set up to 4 different defrost lockout periods. The lockout prevents the unit from going into a defrost
cycle during peak kitchen use. Note: The 24-hour clock must be set for this feature to operate correctly.
Data Storage
The control comes equipped with 72 hours worth of data storage capability including:
• Records cabinet air temperatures every 6 minutes, needed to document "Due Diligence" in accordance with
HAACP standards.
• Records alarm events.
• Records diagnostic test of each sensor every 24 hours.
• Records failed security attempts.
• Records door open cycles.
• Records defrost cycles (refrigerator and freezer models only).
Note: The 24-hour clock and the date must be set for the above information to be recorded at the correct time
and date.
Communication Ability
An RS485 port is available as a means of retrieving information from the stored data.
Smart Recovery
In the event that a sensor fails, the INTELA-TRAUL
cycles that it recorded over the previous 72 hours in order to maintain the operation of the unit until service arrives.
Alarms (See the following pages for explanations)
• High Cabinet Air Temperature
• Low Cabinet Air Temperature
• Loss Of Power
• CONDENSERCLEAN*
• Sensor Failures
* Not Available On Remote Models
VII. INTELA-TRAUL
CONTROL FEATURES:
®
control is water resistant not only from the face of the control, but also from the rear of the
®
control will maintain the same compressor operation & defrost
®