Nordson Rhino VE Quick Start Manual
Nordson Rhino VE Quick Start Manual

Nordson Rhino VE Quick Start Manual

Pneumatic level detect modules
Hide thumbs Also See for Rhino VE:

Advertisement

Quick Links

Description
See Figure 1. Level Detect modules use roller plunger
limit switches on guide rails to monitor the distance
between the bottom of the follower and the base surface
of the bulk unloader frame.
The actuating rod connects to the bulk unloader
crossover bar. It actuates each roller plunger on the limit
switches during the downward movement of the
follower/platen.
CROSSOVER BAR
FOLLOWER
Figure 1
Typical Level Detect Assembly (Large Frame Shown)
E 2012 Nordson Corporation
Pneumatic Level Detect Modules
The assembly detects two conditions during the
downward movement of the follower:
S
Follower in drum
S
Drum Empty
Refer to the Adjusting Limit Switches section for more
information on setting the limit switches.
ROLLER PLUNGER
LIMIT SWITCH
Rhino
VE/CE
r
ACTUATING ROD
GUIDE RAILS
Part 1603025--01

Advertisement

loading

Summary of Contents for Nordson Rhino VE

  • Page 1 Refer to the Adjusting Limit Switches section for more follower/platen. information on setting the limit switches. CROSSOVER BAR ACTUATING ROD GUIDE RAILS FOLLOWER ROLLER PLUNGER LIMIT SWITCH Figure 1 Typical Level Detect Assembly (Large Frame Shown) Part 1603025--01 E 2012 Nordson Corporation...
  • Page 2 Rhino VE/CE Pneumatic Level Detect Modules Repair Wiper Seal 1. See Figure 2. Remove the screws (6) and Repairs consist of replacing the actuating rod wiper seal washers (5) securing the cover (4) to the base along with replacing and adjusting the roller plunger plate (9).
  • Page 3: Limit Switch

    Rhino VE/CE Pneumatic Level Detect Modules Limit Switch 1. See Figure 2. Remove the screws (6) and 6. Connect the tubing (4) to the fittings (3). washers (5) securing the cover (4) to the base 7. Slide the limit switch (2) toward the actuating rod (8) plate (9).
  • Page 4: Adjusting Limit Switches

    Rhino VE/CE Pneumatic Level Detect Modules Adjusting Limit Switches See Figure 4 and review the following switch descriptions 3. Slide the switch bracket (3) to the desired height and in Table 1 before making adjustments. Perform the tighten the set screws (1).
  • Page 5 Rhino VE/CE Pneumatic Level Detect Modules Notes: Part 1603025--01 E 2012 Nordson Corporation...
  • Page 6 Rhino VE/CE Pneumatic Level Detect Modules Parts Small Frame Level Detect Module See Figures 5 and refer to the following parts list. To order parts, call the Nordson Customer Service Center or a local Nordson representative. WIPER ORIENTATION Figure 5...
  • Page 7 Rhino VE/CE Pneumatic Level Detect Modules Item Part Description Quantity — 1097228 Module, level detect, pail, CE 1081672 S Bracket, mounting, rod 1084350 S Screw, socket, set, M6 x 6 mm 1082144 S Collar, split, 0.75 ID x 1.50 OD x 0.50...
  • Page 8 Parts Item Part Description Quantity — 1097216 Level detect module, drum, Rhino VE, CE 1081672 S Bracket, mounting, rod 1084350 S Screw, socket, set, M6 x 6 mm 1082114 S Collar, split, 0.75 ID x 1.50 OD x 0.50 982028...
  • Page 9 Figure 7 Parts (Continued) Item Part Description Quantity — 1097216 Level detect module, drum, Rhino VE, CE 1081670 S Bracket 345913 S Washer, flat, 1/4 345750 S Screw, socket, 1/4-20 x 0.750 1082172 S Collar, split, threaded,1/2-13 x 1.13 OD x 0.50...
  • Page 10 Rhino VE/CE Pneumatic Level Detect Modules Notes: Issued 12/12 Original copyright date 2012. Nordson and the Nordson logo, and Rhino are registered trademarks of Nordson Corporation. All other trademarks are the property of their respective owners. Part 1603025--01 E 2012 Nordson Corporation...