DIAGNOSTIC
TEST
STOP KEY TEST
Notes: (1) Only used on machines that support the Active Status Light feature.

P62, P80, and P82 consoles

Menu path: Hardware Validation Tests (5,1,7,6,5,7,6,1) > System Settings > System
Tests.
On P62, P80, and P82 consoles, the diagnostic tests are located in the Hardware Validation
System Tests menu.
SYSTEM TESTS
AUTO STOP
TEST
BELT SPEED
1
Upper PCA board
2
Lower PCA board
• A/D - lift motor incline position potentiometer A/D number.
• SEC - UP/DWN command response delay between the
2
LPCA
.
• Glitches - Momentary failures in the A/D potentiometer output. If
there are more than 50 Glitches, the lift motor should be replaced.
.
Menu path: MACHINE TEST > STOP KEY TEST
(P10, P30 consoles only)
Verifies the Stop Key and E-Stop function
Test sequence steps;
1.  StopKey test - Press the Stop Key
2.  Lanyard ESTOP test- Pull the lanyard to trip the emergency stop
function.
3.  Exit test - Press the Stop button to reset and exit test.
Menu path: MACHINE TEST > AUTO STOP TEST
Test parameters;
• Status - User detected on running belt
• Step Count - Average # of footplants. Footplant averaging delay reset
with each speed change.
Menu path: MACHINE TEST > BELT SPEED TEST
3 Standard Service and Diagnostics Software
Hardware Validation Service Menu (51765761)
TEST DESCRIPTION
TEST DESCRIPTION
1
UPCA
and
Page 25