5.2
Parameter Setting
5.2.1
Selection of input method (Pr. 304) (FR-A700/F700 SERIES)
Parameter
Number
304
Digital input and analog input compensation enable/disable selection
Pr. 304 Setting
0
1
2
3
4
*2
10
11
12
13
14
*2
9999 (initial value)
*1
Use terminal 1 for analog input compensation. Refer to the inverter instruction manual for details of terminal 1.
*2
These parameters can be set for the FR-A700 series only. Refer to page 35 for details of torque command value input.
REMARKS
• Signal X12 to X15 become invalid when 0 to 4 are set in Pr. 304.
• Refer to page 24 for BCD code/ binary input example.
Name
BCD Code Input
3-digit
3-digit
4-digit
4-digit
Binary Input
12-bit
12-bit
12-bit
Torque command value input
16-bit
16-bit
16-bit
Torque command value input
No function
PARAMETERS
Initial
Setting Range
Value
0 to 4,10 to 14, 9999
Availability of Analog
Input Compensation
*1
( : enabled, ×: disabled)
×
×
×
×
9999
5
27