▶ Pull out the electric cord from the connecting jack and
also take out the plug from the outlet.
Don't turn off the power soon after using the incubator,
as this may cause a break down due to moisture left
inside the main controller. At this time, it's better to
firstly remove the water inside of the incubator and dry
by operating it for 1hour and then turn it off or open the
view window and dry it naturally for 2~3 hours and,
then, re-operate it, which may lengthen the life time of
incubator.
(Set humidification function OFF. / Refer to the page 18.)
How to disassemble and clean the incubator
1
Unlock and remove the locking buttons for
four parts at the front and back of incubator
by pulling them forward.
2
The bottom part of incubator should be thoroughly cleaned
with water and dried. The upper part should be naturally dried
in the well-ventilated place for about one day to remove
moisture left inside of the incubator after hatching thoroughly.
Don't clean the product with organic solvents such as
benzene, thinner, etc. which may cause deformation or
decoloration of the plastic parts.
3
▶ When using humidification function, a lot of alien matter
sticks to the humidification heating element ⓐ. This may not
cause failure, but when terminating incubation please clean
the humidifying heater lightly with a soft brush.
▶ If you place the main body(upper part) on the floor,
please don't let the humidification heating part touch with the
floor.
If you inflict impact on the humidification heating part or
scrape it with a sharp instrument, the humidifying heater
will be damaged.
We kindly recommend you to use distilled water
In order to reduce a foreign substance on the
humidifying heater device.