USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
SET UP(Other Functions)
T.CAL
Temperature
Calibration
H.CAL
Humidity
Calibration
Abnomal
High Alarm
Abnomal
low Alarm
Factory setting
Easy Function Operation
Function
Automatic Mode
Incubation
Other(Manual) Mode
Incubation
How to change Setting
under Incubation
Incubation
Termination
Incubator Initialization
(Factory Setting)
How to change
How to turn off
Humidification Function
In case of low humidity
Egg Turning Test
Egg Incubator Hatcher Rcom USB and Pro 50 User Manual
1. Introduction
Screen
on Incubation
Screen
on Incubation
incubation
5 Sec.
▶ Push SET UP key and then select each function icon using
Be sure to read CAUTIONS. We do no recommend customers
WARNING
to recalibrate by their own. If you need to recalibrate, please
Fatal Damage
with Incorrect Calibration
ask purchase place.
Be sure to read CAUTIONS. We do no recommend customers
WARNING
to recalibrate by their own. If you need to recalibrate, please
Fatal Damage
ask purchase place.
with Incorrect Calibration
Alarm sounds when incubator temp. is higher than setting value
because of room temp. change or heating system disorder
* Setting Range : 0.0
~ 5.0
Alarm sounds when incubator temp. is lower than setting value
because of room temp. change or heating system disorder
* Setting Range : 0.0
~ -5.0
o
Selecting Centigrade (
C) and Fahrenheit (
o
* Default Value : Centigrade (
C)
LCD Backlight management setting
* Always On : Always BackLight On
* Event On
: 20 Sec. ON with Key input
ON/OFF Setting for Melody, other alarms
* Default Value : ON
It returns to factory setting when you change the initial setting at discretion.
Basic information of Incubator (versoin Indication)
put some water after take off label from the back and attach to the window.
If you want to change setting value, keep pressing "SET" button and change the value.
Select
the Species of Bird
Select
the Species of Bird
Once: Temp. Setting
4 times: Humidity Setting
7 times:
Egg Turning Angle Setting
9 times: Egg Turning Interval Setting
System finish
Are you sure?
"All Reset"
UNDER 30%
Setting Value
Check
(6) SET UP(Other Functions) /
Easy Function Operation
UP/DOWN key(ENTER)
(Default Setting : 2.0 )
(Default Setting : -3.0 )
o
F)
* Always Off : Always BackLight Off
* Default Value : Always On
2 Sec.
Temp. Setting
Humid. Setting
Egg Turning Angle Setting
Egg Turning Interval Setting(Incubation day)
Select YES
"OFF"
Need help?
Do you have a question about the USB 50 and is the answer not in the manual?
Questions and answers