USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
Instructions for Disassembling and Cleaning
Power cord must be removed from the outlet of the
machine.
▶ If you turn the incubator off and then leave the incubator
door closed after high humidity incubation, accumulated
moisture inside the incubator evaporates and sticks to
electric and electronic circuits. This could cause problems,
be sure to open the incubator door and completely remove
moisture inside of incubator.
[ Cleaning the Controller Unit ]
▶ As shown in the picture, unscrew 6 screws
located in the corners of the incubators
cover with the screwdriver and open the
cover.
▶ Remove all the remaining water from the
humidity unit.
If a lot of dirty substance(scale) has
formed in the humidifier unit, soaking
it in vinegar overnight will neatly clean
the humidifier unit.
If a lot of scale has formed it is likely you
are not using distilled water, please use
distilled water as it prolongs incubator life.
▶ dirty substance(scale) can form in the
humidity unit and pan should be removed
by using a vacuum cleaner, brush and/or
further cleaning aided by vinegar.
If there are any dirty substance(scale)
in the humidifier unit and pan, it must
be removed.
DIGITAL INCUBATOR
Egg Incubator Hatcher Maru Pro User Manual
6. How to Clean your MARU
humidity unit
(1) Instructions for
Disassembling and Cleaning
Power Cord
Vinegar
OFF
21