Troubleshooting
10 Troubleshooting
10.1 Customer Service
Contact for repairs and issues with the machine:
Dürkopp Adler AG
Potsdamer Str. 190
33719 Bielefeld, Germany
Tel. +49 (0) 180 5 383 756
Fax +49 (0) 521 925 2594
Email: service@duerkopp-adler.com
Internet: www.duerkopp-adler.com
10.2 Messages of the software
Please contact customer service if an error occurs that is not described
here. Do not attempt to correct the error yourself.
Error 01
Seam program empty
Error 02
Seam not enabled
Error 05
I/O communication error
Error 06
Step pulses not valid
Operating Instructions 2112-5 - 00.0 - 02/2020
Code
Meaning
Current seam program
empty; possibly, distances
and routes have not been
input or the entire program
was erased
Current seam program not
activated; number appears
black on white
Error transmitted between
control unit and I/O module
Clamp slide not positioned
correctly
Remedial action
Insert program values
manually, copy from other
program or retrieve from
ROM (parameter INIT)
Press <ENT> key to activate
program
Check connecting cable;
if not OK, replace control unit
and/or I/O module
Check sensor connection
to clamp motor; check
connecting cable between
adapter board 9020020 and
I/O module 9020013; replace
adapter board 9020020